Paradyne CSU, DSU, 9126-II, 9128-II manual General System Options 2

Models: CSU, DSU 9126 9126-II 9128-II

1 470
Download 470 pages 16.65 Kb
Page 76
Image 76

4. Configuration Options

Table 4-5. General System Options (2 of 3)

Secondary Clock Source

Possible Settings: Net1, DSX, Internal, DBM

Default Setting: Internal

Provides a secondary clock source when the primary clock source fails. The source selected for this configuration option provides all of the timing within the unit and the clocks for all of the external interfaces.

The clock source will switch back to primary when the primary clock source returns and is stable for 10 seconds. If the secondary clock source fails, the clock source will switch to internal. The clock source will switch back to primary when the primary clock source returns and is stable for 10 seconds.

NOTE: For the Primary and Secondary Clock Source options, only Internal can be selected for both options. All other selections must have different settings (e.g., if Primary Clock Source is set to Net1, Secondary Clock Source cannot be set to Net1).

Net1 – The secondary clock is derived from the Network1 T1 interface.

DSX – The secondary clock for the unit is derived from the DSX-1 interface. This setting only appears if the DSX-1 interface is enabled.

Internal – The secondary clock is the internal clock.

DBM – The secondary clock is derived from the DBM. This selection only appears if the

DBM is installed and enabled.

4-32

September 2002

9128-A2-GB20-80

Page 76
Image 76
Paradyne CSU, DSU, 9126-II, 9128-II manual General System Options 2