8. Troubleshooting
8-20 September 2002 9128-A2-GB20-80
Starting and Stopping a Test
Use this procedure to start, monitor, or abort specific tests. To abort all active tests
on all interfaces, see

Aborting All Tests

on page 8-21.
Start or stop an individual test using the same procedure.
Procedure
To start and stop a loopback or a send-pattern test:
1. Follow this m enu selection sequence:
Main Menu
Test
2. S elect an interface and test (e.g., Network, Data Port, or ISDN PVC Tests) and
press Enter.
The selected test screen appears. Start appears in the Command column.
Inactive appears in the Status column.
3. S elect the Port number and press Enter.
4. S elect the DLCI number and press Enter if a PVC test has been selected.
The cursor is positioned at Start in the Command column of the first available
test and is highlighted.
5. To start the test, highlight Start under Command for the test you want to r un
and press Enter. Stop now appears and is highlighted, and the status of the
test changes to Active.
The length of time that the test has been running is shown in the Result
column.
6. To stop the test, press Enter to send the Stop command. Start reappears
and the status of the test changes back to Inactive.
When the status of a test is . . . The only command ava ilable is . . .
Inactive Start
Active Stop