Paradyne 9126 Device Problems 2 Symptom Possible Cause Solutions, Improperly Configured Unit on

Models: CSU, DSU 9126 9126-II 9128-II

1 470
Download 470 pages 16.65 Kb
Page 279
Image 279

8. Troubleshooting

Table 8-2. Device Problems (2 of 2)

Symptom

Possible Cause

Solutions

 

 

 

Cannot access the unit

Login or password is

Reset the unit (see Restoring

or the menu-driven

incorrect, COM port is

Communication with an

user interface.

misconfigured, or the unit is

Improperly Configured Unit on

 

otherwise configured so it

page 8-4).

 

prevents access.

Contact your service

 

 

 

 

representative.

 

 

 

Failure xxxxxxxx

The unit detects an internal

Record the 8-digit code from

appears at the top of

software failure.

the System and Test Status

the System and Test

 

screen.

SelfStatus-Testscreen,Results.at

 

TReset the unit and try again.

 

 

Contact your service

 

 

representative and provide the

 

 

8-digit failure code.

 

 

 

An LED appears

LED is burned out.

Run the Lamp Test. If the LED in

dysfunctional.

 

question does not flash with the

 

 

other LEDs, then contact your

 

 

service representative.

 

 

 

Not receiving data.

Network cable loose or

TReconnect or repair the cable.

 

broken.

Call the network service

 

 

 

 

provider.

 

 

 

Receiving data errors

Frame Relay Discovery is

Change the DLCI Type for each

on a multiplexed DLCI,

being used for automatic

network DLCI from Multiplexed to

but frame relay is okay.

DLCI and PVC

Standard, turning off multiplexing.

 

configuration.

 

 

The equipment at the other

 

 

end is not frame relay

 

 

RFC 1490-compliant.

 

 

 

 

9128-A2-GB20-80

September 2002

8-15

Page 279
Image 279
Paradyne CSU, DSU, 9126-II, 9128-II Device Problems 2 Symptom Possible Cause Solutions, Improperly Configured Unit on