7. Operation and Maintenance

Table 7-12. PVC Connection Status (2 of 2)

Field

Status

Status

What It Indicates

 

Identifies whether the physical

 

interfaces, LMIs, and DLCIs are all

 

enabled and active for this PVC

 

connection.

Active *

The PVC is currently active.

Inactive

TThe PVC is inactive because:

 

– Alarm conditions and network

 

and SLV communication

 

status indicate that data

 

cannot be successfully

 

passed.

 

– The unit has disabled the

 

interface or frame relay link

 

due to internal operating

 

conventions.

 

– Activation of an alternate

 

virtual circuit is not warranted;

 

that is, no alarm condition on

 

the primary destination link

 

has been detected.

Disabled

TThe PVC cannot be activated and

 

is essentially disabled as a result

 

of how the unit was configured.

 

Possible causes:

 

– The physical interface at one

 

or both ends of the PVC is/are

 

disabled.

 

– The frame relay link on one or

 

both ends of the PVC is/are

 

disabled.

Invalid

TSome portion of the PVC

 

connection is not fully configured.

 

 