8. Troubleshooting
9128-A2-GB20-80 September 2002 8-11
OOF at Network 1 An Out of Frame (OOF)
condition is detected on the
network interface.
Incompatible framing
format between the
network and the
FrameSaver unit.
Network cabling
problem.
T1 facility problem.
Check that the framing format
for the network interface is
correct.
Check that the network cable is
securely attached at both ends.
Contact your network provider.
Path

IP_ Address

Down, DLCI
nnnn
1A path on the network
interface is unavailable. Determine why the path went
down.
Power Supply/Fan
Alarm The power supply output
voltage has dropped below
the specified tolerance level
required for the system. Or
one or both fan trays are not
operating properly.
Check the LEDs on the power
supply and fan trays to determine
which may have failed, then
replace the failed component.
Primary Clock Failed A failure of the configured
primary clock source for the
unit was detected and the
secondary clock i s
providing the timing for the
unit.
This condition clears when
the configured primary
clock is restored.
Check that the network cable is
securely attached at both ends.
Contact your network provider.
Primary & Secondary
Clocks Failed A failure of both clock
sources configured for the
unit was detected.
This condition only applies
to T1 network and DSX-1
interfaces. It clears when
the configured primary
clock is restored.
Table 8-1. Alarm Conditions (5 of 7) Alarm Condition What It Indicates What T o Do
1

nnnn

indicates a DLCI number of 16 through 1007.
2
frame relay link
is one of the following:
Net1-FR1. The frame relay link specified for the network inter face, Network 1.
Port-
n
. The frame relay link associated with a user data port.
ISDN Link Name
on a non-network IS D N DBM interface.
3Does not apply to a TS Access Management Link DLCI.