8. Troubleshooting

Send Pattern

This test sends packets filled with a hexadecimal 55 test pattern and sequence number over the selected interface and DLCI to another FrameSaver device.

To send a pattern test on a link:

Main Menu Test

[Network PVC Tests/Data Port PVC Tests/

ISDN Call/PVC Tests]

 

 

 

 

 

If the selected DLCI is

 

 

And the default

configured as . . .

 

Then . . .

Rate (Kbps) setting is . . .

 

 

 

 

Standard

 

(Disruptive) appears

100% of CIR

 

 

after Test

 

 

 

 

 

Multiplexed

 

(Non-Disruptive)

10% of CIR

 

 

appears after Test

 

 

 

 

 

If the CIR is zero, the pattern will be sent at a rate of 1000 bps.

Monitor Pattern

This test monitors packets filled with a hexadecimal 55 test pattern and sequence number over the selected interface and DLCI to another FrameSaver device.

To monitor a pattern test on a link:

Main Menu Test[Network PVC Tests/Data Port PVC Tests/

ISDN Call/PVC Tests]

The current number of sequence and data errors are shown under the Result column when the FrameSaver unit is in sync. An Out of Sync message appears when 5 frames out of 25 are missing or out of sequence.

These error counts are updated every second. If the maximum count is reached, 99999+ appears in these fields.

8-24

September 2002

9128-A2-GB20-80

Page 288
Image 288