F. Technical Specifications

Table F-3. 14-Slot 9000 Series Access Carrier Technical Specifications (2 of 2)

Specification

Criteria

 

 

 

 

 

 

 

 

Physical Environment

 

 

 

 

Operating temperature

35° F to 122° F (1.7° C to 50° C)

 

Storage temperature

–4°F to 158° F ( –20°C to 70° C)

Relative humidity

5% to 85% (noncondensing)

 

Shock and vibration

Withstands normal shipping and handling

 

 

 

 

 

Physical Dimensions

 

 

 

 

Height

10.5 inches (26.7 cm) or 6U

 

Width

17.2 inches (43.7 cm)

 

Depth

14.3 inches (36.3 cm)

 

 

 

Weight

Empty access carrier (without power supply)

 

11 lbs. 6 oz. (5.16 kg)

 

 

 

 

 

 

AC Power Requirements

 

 

 

 

AC Power Supply

90 to 265 VAC, 50/60 Hz ± 3A maximum

DC Power Supply

–48 VDC, 6.6 amps, 316 watts

 

 

 

 

Heat Dissipation (Max.)

Fully loaded access carrier

 

227 VAC

585 Btu per hour maximum

 

–48 VDC

465 Btu per hour maximum

 

 

 

 

 

 

Typical Power Consumption

 

 

 

 

AC Power Supply

 

 

 

 

1 power supply installed

100 VAC

60 Hz

1.7 amps

171 watts

 

120 VAC

60 Hz

1.03 amps

60 watts

 

100 VAC

50 Hz

1.15 amps

60 watts

 

Result: 207 Btu per hour

 

2 power supplies installed

100 VAC

60 Hz

1.25 amps

64.5 watts

 

120 VAC

60 Hz

1.5 amps

177 watts

 

230 VAC

50 Hz

0.9 amps

172 watts

 

Result: 221 Btu per hour

 

DC Power Supply

 

 

 

 

1 power supply installed

104 watts at –48 VDC

 

 

Result: 355 Btu per hour

 

2 power supplies installed

124 watts at –48 VDC

 

 

Result: 423 Btu per hour

 

 

 

 

 

 

F-6

September 2002

9128-A2-GB20-80

Page 446
Image 446
Paradyne 9128-II, CSU, DSU, 9126-II manual AC Power Requirements, Heat Dissipation Max, Typical Power Consumption