B. SNMP MIBs and Traps, and RMON Alarm Defaults

Standards Compliance for SNMP Traps

This section describes the FrameSaver unit’s compliance with SNMP format standards and with its special operational trap features.

All traps have an associated string to help you decipher the meaning of the trap. Strings associated with an interface with a substring containing $ifString have the following format:

‘DLCI $dlciNumber “$circuitId” of $ifName frame relay link “$linkName”.’

$dlciNumber is the DLCI number. DLCI $dlciNumber “$circuitId” only appears when a DLCI is associated with the trap.

$circuitId is the name given to the circuit. It can be an empty string, or a 1– 64 byte string within quotes (e.g., “Chicago to New York”), and only appears when a DLCI with “circuitID” is associated with the trap.

$linkName is the name given to the link. Frame relay $linkName only appears when a frame relay link has been named and is associated with the trap.

$ifName is the string returned for the SNMP ifName variable.

Examples:

‘DLCI 100 “Chicago to New York” of Network T1 frame relay link’ In this example, a DLCI and a frame relay link are associated with the trap.

Typically, the $circuitId is a coded string encoded by the network service provider. The following shows an example.

‘DLCI 100 “cc0402–dec0704.RG21” of Network T1 frame relay link’

he unit supports the following:

Trap: warmStart

Trap: authenticationFailure

Traps: linkUp and linkDown

Traps: enterprise-Specific

TTraps: RMON-Specific

Trap: dialControl

These traps are listed in alphabetical order within each table.

B-8

September 2002

9128-A2-GB20-80

Page 356
Image 356
Paradyne CSU, DSU, 9126-II, 9128-II manual Standards Compliance for Snmp Traps, Examples