7. Operation and Maintenance
9128-A2-GB20-80 September 2002 7-29
Network LMI-Reported DLCIs Status
Network LMI-reported DLCI statuses are selected from the Status menu.
Main Menu
Status

LMI Reported DLCIs

The LMI Reported DLCIs screen displays the status and CIR (if suppor ted by the
switch) for each DLCI, whether the DLCI is configured or not.
LMI-Reported DLCIs Status Screen Example
An asterisk (*) next to the DLCI indicates that the DLCI has been configured for the
link.
DLCIs without an asterisk have not been configured in the unit. These DLCIs pass
through the unit transparently, without being monitored and with no
demultiplexing/multiplexing of management diagnostics or user data being
performed. Only DLCIs on the Net1-FR1 and Port-1 frame relay links appear on
this screen; nonconfigured DLCIs on other links are discarded.
main/status/lmi_dlcis 9128-II
Device Name: Node A 5/26/2000 23:32
frame relay link
LMI REPORTED DLCIs Page 1 of 2
DLCI STATUS CIR (bps) DLCI STATUS CIR (bps)
* 300 Active 16000 * 622 Active 32000
* 305 Inactive * 624 Active 32000
* 400 Deleted * 625 Deleted
* 410 Inactive * 713 Active 32000
411 Inactive * 822 Active 32000
420 Inactive 32000 * 1002 Active 32000
430 Active
501 Inactive
511 Active 256000
520 Active 64000
* DLCI is configured on the Frame Relay Link.
--------------------------------------------------------------------------------
ESC for previous menu MainMenu Exit
Refresh PgUp PgDn NextLink PrevLink