2. User Interface and Basic Operation

Screen Work Areas

here are two user work areas:

TScreen area – Where you input information into fields.

Function keys area – Where you perform specific screen functions.

 

Below is a sample configuration screen.

 

 

 

Model Number

 

 

Date and Time

 

Menu Path

main /config/system/slv

9128-IISLV

 

Device Name: Node A

 

08/23/2002 10:59

 

 

SERVICE LEVEL VERIFICATION SYSTEM OPTIONS

Device Name

 

 

 

 

 

SLV Sample Interval (secs):

60

 

 

SLV Synchronization Role:

Tributary

 

 

SLV Type: Standard

 

 

 

SLV Delivery Ratio:

Disable

Screen Area

 

DLCI Down on SLV Timeout:

Enable

 

 

SLV Timeout Error Event Threshold:

3

 

 

SLV Timeout Clearing Event Threshold:

1

 

 

SLV Round Trip Latency Error Threshold (ms): 10000

 

 

SLV Latency Clearing Event Threshold:

2

 

 

SLV Packet Size (bytes):

64

 

-------------------------------------------------------------------------------

 

Ctrl-a to access these functions, ESC for previous menu

MainMenu Exit

Function Keys Area

 

 

 

 

Save

 

 

Message Area

 

 

 

Screen Format

Description

 

 

Menu Path

Menu selections made to reach the current screen.

 

Device Name

Customer-assigned identification of the FrameSaver unit.

 

9126, 9126-SLV, 9126-IISLV, FrameSaver unit’s model number.

 

 

9126-IIR, 9126-IIRSLV,

 

 

 

9128-II, or 9128-IISLV

 

 

 

Screen Area

Selection, display, and input fields for monitoring and

 

 

maintaining the FrameSaver unit.

 

 

Function Keys Area

Specific functions that can be performed by pressing a

 

 

specified key, then pressing Enter.

 

 

Message Area

System-related information and valid settings for input

 

 

fields are in the lower left corner.

 

 

 

System and Test Status messages are in the lower right

 

 

corner.

 

9128-A2-GB20-80

September 2002

2-5

Page 33
Image 33
Paradyne 9126-II, CSU, DSU, 9128-II manual Screen Work Areas, Screen Format Description