8. Troubleshooting

Alarms

The following table describes the alarm conditions that will generate an SNMP trap for a physical interface, and the frame relay LMIs and DLCIs. These alarm conditions also generate Health and Status messages seen on the System and Test Status screen.

Main Menu Status System and Test Status

Table 8-1. Alarm Conditions (1 of 7)

Alarm Condition

What It Indicates

What To Do

 

 

 

AIS at DSX-1

For the DSX-1 interface, the

For the DSX-1 interface, check the

 

attached DTE is

DTE attached to the interface.

 

transmitting an AIS.

 

 

 

 

AIS at Network 1

An Alarm Indication Signal

For the network interface, report

 

(AIS) is being received by

the problem to your T1 service

 

the interface. AIS is an

provider.

 

unframed, all ones signal.

 

 

 

 

CTS down to

The CTS control lead on the

Check DTR and RTS from Port-1.

Port-1 Device

device’s interface is off.

TVerify that the port is enabled.

 

 

Check DTR from the user data

 

 

port.

 

 

 

DBM BRI Card Failed

The ISDN BRI DBM failed

Reset the FrameSaver unit (Main

 

to pass the self-test.

MenuControl Reset Device).

 

 

If the DBM fails again, contact

 

 

your service representative.

 

 

 

DLCI nnnn Down,

The DLCI for the specified

Verify that the network LMI is up. If

frame relay link 1,2

frame relay link is down.

it is, contact your network

 

 

provider, or your ISDN service

 

 

provider if an ISDN Link Name is

 

 

the link.

 

 

 

DTR Down from Port-1

The DTR control lead on

Examine the attached DTE and

Device

the device connected to

cable connected to the system’s

 

Port-nis disasserted.

port.

 

The DTR control lead on

Check that the port cable is

 

the device connected to the

Tsecurely attached at both ends.

 

specified port is off. This

Check the status of the

 

message applies to data

 

attached equipment.

 

ports that act as DCEs.

 

 

 

 

 

1nnnn indicates a DLCI number of 16 through 1007.

2frame relay link is one of the following:

Net1-FR1. The frame relay link specified for the network interface, Network 1.

Port-n. The frame relay link associated with a user data port.

ISDN Link Name on a non-network ISDN DBM interface.

3Does not apply to a TS Access Management Link DLCI.

9128-A2-GB20-80

September 2002

8-7

Page 271
Image 271
Paradyne CSU, DSU, 9126-II manual Alarms, Alarm Conditions 1 What It Indicates What To Do, Menu → Control → Reset Device