4. Configuration Options

Assigning Frame Relay Time Slots to the Network Interface

Before assigning network time slots for use by frame relay traffic, configure the

Network physical and Frame Relay options (if needed), then allow Time Slot

Discovery to autodetect and assign the appropriate time slots to frame relay.

If there are multiple Frame Relay data links on the network interface, or if Time Slot Discovery is not currently active, you can manually assign time slots on the network interface for frame relay traffic using the Frame Relay Network Assignments screen. This screen is read-only when Time Slot Discovery is set to Enable for the network interface.

Frame Relay Network Time Slot Assignment Screen Example

main/config/tslot_assign/frame_relay

 

 

 

9128-II

Device Name: Node A

 

 

 

 

5/26/2000 23:32

 

 

FRAME RELAY NETWORK 1 ASSIGNMENT

 

 

 

 

 

Time Slot Discovery: Disable

 

 

N01

N02

N03

N04

N05

N06

N07

N08

Available Available Available Available Available Available Available Available

N09

N10

N11

N12

N13

N14

N15

N16

Available Available FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1

N17

N18

N19

N20

N21

N22

N23

N24

FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1 FrameRly1

--------------------------------------------------------------------------------

Ctrl-a to access these

functions, ESC for previous menu

MainMenu Exit

Save PgDn

PgUp

ClearAll

DSXAssign

 

Value

Meaning

 

 

Time Slot

Specifies whether the time slots used for frame relay traffic should be

Discovery

discovered from the network interface upon detection of an LMI

 

failure. This option allows additional time slots to be added without

 

manually reconfiguring the device.

 

 

N tt

This field represents time slot tt of the selected network interface.

 

 

Assigned

The time slot is already assigned to something other than frame

 

relay, so it is unavailable. Assigned time slots cannot be modified

 

from this screen.

 

 

Available

The time slot is currently unassigned.

 

 

FrameRly1

The time slot is assigned to frame relay service, link 1.

 

 

For easy movement between screens, select the DSXAssign function key to go directly to the DSX-1 to Network Assignments screen.