7. Operation and Maintenance

Table 7-9. Test Status Messages (2 of 2)

Message

What It Indicates

 

 

Monitor Pttn Active, Interface 2

A Monitor Pattern test is active on the specified

 

interface.

 

This test cannot be activated on user data ports that

 

have Port Use set to Frame Relay.

 

 

Network Initiated ISDN BRI Test

An ISDN test has been started by the ISDN BRI

Active

network and it is currently active.

 

 

Send Pttn Active, DLCI nnnn,

A selected Send Pattern test is active on the

frame_relay_link 1 ,3

specified DLCI for the specified frame relay link.

Monitor Pttn Active, DLCI nnnn,

A selected Monitor Pattern test is active on the

frame_relay_link 1 ,3

specified DLCI for the specified frame relay link.

Test Call Active, ISDN Link Name

A test call is active on the specified frame relay link,

 

the link being the ISDN Link Name assigned in the

 

ISDN Link Profile.

 

This message would only appear for units with the

 

ISDN DBM feature.

 

 

1frame relay link is one of the following:

Net1-FR1. The frame relay link specified for the network interface, Network 1.

Port-nfor a 1-slot unit, or SsPort-nfor a NAM in a multislot housing (the frame relay link associated with the specified user data port in the specified slot).

ISDN Link Name on a non-network ISDN DBM interface.

2Interface is one of the following:

Network 1

DSX-1

Port-n

ISDN, BRI or PRI

3nnnn indicates a DLCI number of 16 through 1007.

7-28

September 2002

9128-A2-GB20-80

Page 210
Image 210
Paradyne 9128-II, CSU, DSU, 9126-II manual Test Status Messages 2 What It Indicates