8. Troubleshooting

Table 8-1. Alarm Conditions (7 of 7)

Alarm Condition

What It Indicates

What To Do

 

 

 

Suboptimal Link Rate,

The specified frame relay

No action required.

frame relay link 2

multilink has failed to

 

 

achieve the configured

 

 

Maximum Link Rate for the

 

 

link.

 

 

his message appears for

 

 

multilink aggregate frame

 

 

relay links if LMI is down on

 

 

any of its constituent links.

 

 

 

 

Two Level-1 Users

Another user with Level-1

Wait until no other Level-1 users

Accessing Device

security access is currently

are accessing the unit if testing or

 

accessing the unit.

configuration will be performed.

 

Be aware that actions of the

 

 

other user may override

 

 

your test commands and

 

 

configuration changes.

 

 

 

 

Yellow at DSX-1

A yellow alarm signal is

Check that the DSX-1 cable is

 

received on the DSX-1

securely attached at both ends.

 

interface. DTE has detected

Check the status of the

 

a LOS or OOF condition.

 

attached equipment.

 

 

 

 

 

Yellow at Network 1

A yellow alarm signal is

 

 

received on the network

 

 

interface.

 

 

TNetwork cable problem.

Check that your network cable

 

 

is securely attached at both

 

 

Tends.

 

T1 facility problem.

Contact your network provider.

 

 

 

1nnnn indicates a DLCI number of 16 through 1007.

2frame relay link is one of the following:

Net1-FR1. The frame relay link specified for the network interface, Network 1.

Port-n. The frame relay link associated with a user data port.

ISDN Link Name on a non-network ISDN DBM interface.

3Does not apply to a TS Access Management Link DLCI.

9128-A2-GB20-80

September 2002

8-13