10. Setting Up NetScout Manager Plus for FrameSaver Devices

Procedure

1.Open a terminal window and go to $NSHOME/usr.

2.Copy an example or interface-specific file to a new file that contains the user history table number.

3.Open the new file using a text editor.

The variables in the file are listed with their OIDs (Object IDs). The frame relay interface number 101015001 must replace @IFN, and the DLCI number to be monitored must replace @DLCI.

Example: frCircuitSentFrames

Change “1.3.6.1.2.1.10.32.2.1.6.@IFN.@DLCI” to “1.3.6.1.2.1.10.32.2.1.6.101015001.301

The only valid interface number for a FrameSaver SLV 9126, 9126-II, 9126-II Router, or 9128-II is 101015001.

4.Edit the new file, as needed.

Refer to Creating .UDH Files and Using Custom History in the NetScout Manager Plus User Guide for additional information.

See Appendix B, SNMP MIBs and Traps, and RMON Alarm Defaults, for OID information for an interface.