5. Configuring the FrameSaver SLV Router
5-4 September 2002 9128-A2-GB20-80
Interface Configuration
The following examples require that IP addresses have been assigned to the
Ethernet and Serial interfaces, and that a passthrough PVC connection exists to
Rtr-S0. Optionally you might also disable bridging.
In the following example, the Serial 0 sub-interface is shown as x. The valid range
is 04,294,967,295.
Procedure
To set up the routers interfaces:
1. If a Net1-FR1 DLCI does not exist:
Create one using the Network Circuit Records screen, then select
CreatePVC.
When the Create PVC using DLCI Number? prompt appears, select
a DLCI and press Enter.
When the Create Pass-Thru PVC Connection to:? prompt
appears, enter Rtr-S0.
Save the configuration.
2. From the Main Menu screen, press Ctrl-a then Shift-r to access the routers
Command Line Interface. Set the IP addresses of the interfaces.
The following example commands:
Set the Ethernet interface address to 10.1.3.1
Set the Serial 0.
x
interface to 172.20.95.2
Disable bridging for both interfaces
Specify that messages for all IP addresses should be routed to the
upstream router at 172.20.95.1
en
config t
int e 0
ip address 10.1.3.1 255.255.255.0
no bridge-group 1
int se 0.x
ip address 172.20.95.2 255.255.255.0
no bridge group 1
exit
ip route 0.0.0.0 0.0.0.0 172.20.95.1
save