5. Configuring the FrameSaver SLV Router

Interface Configuration

The following examples require that IP addresses have been assigned to the Ethernet and Serial interfaces, and that a passthrough PVC connection exists to Rtr-S0. Optionally you might also disable bridging.

In the following example, the Serial 0 sub-interface is shown as x. The valid range is 0–4,294,967,295.

Procedure

To set up the router’s interfaces:

1.If a Net1-FR1 DLCI does not exist:

Create one using the Network Circuit Records screen, then select CreatePVC.

When the Create PVC using DLCI Number? prompt appears, select a DLCI and press Enter.

When the Create Pass-Thru PVC Connection to:? prompt appears, enter Rtr-S0.

Save the configuration.

2.From the Main Menu screen, press Ctrl-a then Shift-r to access the router’s Command Line Interface. Set the IP addresses of the interfaces.

The following example commands:

Set the Ethernet interface address to 10.1.3.1

Set the Serial 0.x interface to 172.20.95.2

Disable bridging for both interfaces

Specify that messages for all IP addresses should be routed to the upstream router at 172.20.95.1

en config t int e 0

ip address 10.1.3.1 255.255.255.0 no bridge-group 1

int se 0.x

ip address 172.20.95.2 255.255.255.0 no bridge group 1

exit

ip route 0.0.0.0 0.0.0.0 172.20.95.1 save

exit

5-4

September 2002

9128-A2-GB20-80

Page 154
Image 154
Paradyne 9128-II, CSU, DSU, 9126-II manual Interface Configuration, Procedure