Lantronix 900-588 manual Connection Settings UDP, To configure a channel’s UDP settings

Models: 900-588

1 74
Download 74 pages 382 b
Page 32
Image 32

 

 

 

 

 

5: Configuration Using Web Manager

 

 

 

 

 

 

 

 

 

 

 

Disconnect Mode Settings

 

 

Description

 

 

 

 

 

 

 

 

 

 

Check EOT (Ctrl-D)

 

 

Select Yes to drop the connection when Ctrl-Dor Hex 04 is

 

 

 

 

 

 

detected. Both Telnet Com Port Cntrl and Check EOT

 

 

 

 

 

(Ctrl+ D) must be enabled for Disconnect with EOT to function

 

 

 

 

 

properly. Ctrl+D is only detected going from the serial port to the

 

 

 

 

 

 

network. The default setting is No.

 

 

 

Inactivity Timeout

 

 

Use this parameter to set an inactivity timeout. The unit drops the

 

 

 

 

 

 

TCP connection to port 10001/10002* if there is no activity on the

 

 

 

 

 

 

serial line before the set time expires. Enter time in the format

 

 

 

 

 

 

mm:ss, where m is the number of minutes and s is the number of

 

 

 

 

 

 

seconds. To disable the inactivity timeout, enter 00:00.

 

 

 

 

 

 

Note*: The default port number for Port 1 is 10001 and 10002 for

 

 

 

 

 

 

Port 2. However, port numbers may be set to a different value.

 

3.When you are finished, click the OK button.

4.On the main menu, click Apply Settings.

Connection Settings - UDP

To configure a channel’s UDP settings:

1.On the main menu, click Connection. The Connection Settings window for the selected channel displays.

2.In the available fields, enter or modify the following information:

Figure 5-8. UDP Connection Settings

Micro125 User Guide

32

Page 32
Image 32