8: Setup Mode: Channel Configuration
Table 8-3. Interface Mode Options
I/F Mode Option 7 6 5 4 3 2 1 0
RS-422 4-wire
0
1
RS-485 2-wire
1
1
Flow
Flow control sets the local handshaking method for stopping serial input /output.
Flow (00) ? _
Use the following table to select flow control options:
Table 8-4. Flow Control Options
Flow Control Option Hex
No flow control
00
XON/XOFF flow control
01
Hardware handshake with RTS/CTS lines
02
XON/XOFF pass characters to host 05
Port Number
The setting represents the source port number in TCP connections. It is the n umber that
identifies the channel for remote initiating connections.
Port No (10001) ? _
The default setting for Port 1 is 10001. The range is 1-65535, except for the f ollowing
reserved port numbers:
Table 8-5. Reserved Port Numbers
Port Numbers Reserved for
1 1024
Reserved (well known ports)
9999
Telnet setup
14000-14009
Reserved for Redirector
30704
Reserved (77F0h)
30718
Reserved (77FEh)
WARNING: We recommend that you not use the reserved port numbers
for this setting as incorrect operation may result.
Use Port 0 for the outgoing local port to change with each connection. T he port range is
50,000 to 59,999. Each subsequent connection increments the number b y 1 (it wraps back
around to 50,000).
Only use this automatic port increment feature to initiate a connection using TCP. Set the port
to a non-zero value when the unit is in a passive mode or when using UDP instead of TCP.