LAT Host Troubleshooting

LAT Configuration

6.2 LAT Host Troubleshooting

By default, the LAT error message codes on the host are not translated into text error mes- sages. If a LAT job fails and appears in the queue with an eight-digit hex result code, the code can be translated by issuing the following commands:

Figure 6-4:Translating LAT Error Codes

$ SHOW QUEUE/FULL/ALL queue_name (note the error code nnnnnnnn)

$ SET MESSAGE SYS$MESSAGE:NETWRKMSG.EXE $ EXIT %Xnnnnnnnn

Table 6-1:Troubleshooting LAT Configurations Using a Port

Area to check

Explanation

The specified node name matches the MPS node name

The specified port name matches the port’s name

Use the Show Server command to verify.

Use the List Port 1 command to verify.

6-2