9.Slide the new optical drive with the retaining bracket into the drive bay from the front until it snaps into position.

PSU

Mem

CPU

Figure 97. Installing the optical drive

10. Connect the power cable

1

and the signal cable

2

to the rear of the new optical drive.

Figure 98. Connecting cables to the rear of the optical drive

11.If necessary, connect the other end of the signal cable to the SATA connector 0 on the system board. See “System board components” on page 38.

12.If you are instructed to return the old optical drive, follow all packaging instructions and use any packaging materials that are supplied to you for shipping.

What to do next:

To work with another piece of hardware, go to the appropriate section.

To complete the installation or replacement, go to “Completing the parts replacement” on page 154.

Replacing the ThinkServer RAID Super Capacitor Module

Attention: Do not open your server or attempt any repair before reading and understanding “Safety information” on page iii and “Guidelines” on page 67.

This topic provides instructions on how to replace the ThinkServer RAID Super Capacitor Module.

This topic applies only to server models that have a ThinkServer RAID Super Capacitor Module installed.

Chapter 6. Installing, removing, or replacing hardware 129