LED

Status

Description

Action

 

 

 

 

 

 

 

 

Ambient temperature

Solid off

The server is running at a normal

 

 

2

 

 

limit LED

 

temperature.

 

 

 

 

 

 

 

 

 

 

Solid on (amber)

The ambient temperature is below

Check the BMC for errors and

 

 

 

 

7°C (44.6°F) or over 40°C (104°F).

run the diagnostic programs. See

 

 

 

 

 

“Using a diagnostic program” on

 

 

 

 

 

page 160.

 

 

 

 

 

 

System fan error LED

Solid off

The system fans are operating

 

 

3

 

 

 

 

 

correctly.

 

 

 

 

 

 

 

 

 

 

Solid on (amber)

One or more system fans are

Check the BMC for errors and

 

 

 

 

running at low speed or have

run the diagnostic programs. See

 

 

 

 

been removed.

“Using a diagnostic program” on

 

 

 

 

 

page 160.

 

 

 

 

 

Note: To identify the failing

 

 

 

 

 

system fans, check the status

 

 

 

 

 

LEDs on the system board. See

 

 

 

 

 

“System board LEDs” on page

 

 

 

 

 

46.

 

 

 

 

 

 

Memory module

Solid off

The memory modules

 

 

4

 

 

status LED

 

are operating at a normal

 

 

 

 

 

temperature.

 

 

 

 

 

 

 

 

 

 

Solid on (amber)

One or more memory modules

Check the BMC for errors and

 

 

 

 

are overheated.

run the diagnostic programs. See

 

 

 

 

 

“Using a diagnostic program” on

 

 

 

 

 

page 160.

 

 

 

 

 

 

Microprocessor

Solid off

The microprocessors are

 

 

5

 

 

status LED (also known

 

operating at a normal

 

 

as CPU error LED)

 

temperature.

 

 

 

 

 

 

 

 

 

 

Solid on (amber)

One or more microprocessors are

Check the BMC for errors and

 

 

 

 

overheated.

run the diagnostic programs. See

 

 

 

 

 

“Using a diagnostic program” on

 

 

 

 

 

page 160.

 

 

 

 

 

 

Rear view of the server

This topic provides information to help you locate the connectors and components on the rear of your server.

22ThinkServer RD540 User Guide and Hardware Maintenance Manual

Page 36
Image 36
Lenovo RD540 manual Rear view of the server