3

4

NIC 1 status LED

NIC 2 status LED

The two NIC status LEDs indicate the LAN status for the Ethernet connector 1 and Ethernet connector 2 on the rear panel of the server.

NIC status LED

Color

Description

 

 

 

On

Green

The server is connected to a LAN.

 

 

 

Off

None

The server is disconnected from a LAN.

 

 

 

Blinking

Green

The LAN is connected and active.

 

 

 

5

System error LED

The system error LED helps you to determine if there are any system errors. When the system error LED is on, check the BMC for errors. Refer to the following table for the error descriptions and actions that you can take.

System error LED

Color

Description

Action

 

 

 

 

 

 

The temperature of the server reached

• Check the BMC for errors and check

 

 

the non-critical temperature threshold.

the system fans.

 

 

 

• Ensure that the ambient temperature

 

 

 

limit LED is off.

 

 

 

 

 

 

The voltage of the server reached the

Replace the system board.

 

 

non-critical voltage threshold.

Note: This procedure must be performed

 

 

 

only by trained service personnel of

 

 

 

Lenovo. See Chapter 8 “Getting

 

 

 

information, help, and service” on page

 

 

 

165.

 

 

 

 

 

 

A fan has been detected to be running at

Check the system fans.

 

 

low speed.

 

 

 

 

 

 

 

A hot-swap fan has been removed.

1. Ensure that the system fans are

 

 

 

connected securely to the system

On

Amber

 

board.

 

2. Reinstall the removed fan or install a

 

 

 

 

 

 

new fan to replace the removed fan.

 

 

 

 

 

 

The power supply has a critical error.

Check the BMC for detailed information.

 

 

 

 

 

 

The power cord has been disconnected

1. Ensure that the power supplies are

 

 

from one power supply or a redundant

installed securely in the server.

 

 

power supply has been removed.

2. Ensure that the power cords are

 

 

 

 

 

 

connected securely to the power

 

 

 

supplies.

 

 

 

3. Install a new power supply to

 

 

 

replace the removed one.

 

 

 

 

 

 

The THERMTRIP# signal is asserted

• Check the BMC for errors and then

 

 

because the system is overheated.

check the system fans.

 

 

 

• Ensure that the ambient temperature

 

 

 

limit LED is off.

 

 

 

 

Off

None

The server is off or the server is on and

 

 

 

is working correctly.

 

 

 

 

 

20ThinkServer RD540 User Guide and Hardware Maintenance Manual

Page 34
Image 34
Lenovo RD540 manual NIC 1 status LED NIC 2 status LED, System error LED