Hot-swap hard-disk-drive status LEDs

Each hot-swap hard disk drive has two status LEDs on the front.

Figure 17. Hot-swap hard-disk-drive status LEDs

 

 

hard-disk-drive activity LED

 

 

hard-disk-drive RAID status LED

Description

 

1

 

2

 

 

 

 

Off

 

Off

The hard disk drive has failed or is

 

 

 

 

 

 

not present.

 

 

 

 

On, green

 

Off

The hard disk drive is present but not

 

 

 

 

 

 

in use.

 

 

 

 

Blinking, green

 

Off

The hard disk drive is active and data

 

 

 

 

 

 

is being transferred.

 

 

 

 

On, green

 

Blinking rapidly (about four flashes

The RAID controller is identifying the

 

 

 

 

per second), amber

hard disk drive.

 

 

 

 

On, green

 

On, amber

The RAID array has failed and cannot

 

 

 

 

 

 

be recovered. You need to recreate a

 

 

 

 

 

 

new array.

 

 

 

 

Blinking, green

 

Blinking slowly (about one flash per

The hard disk drive is being rebuilt.

 

 

 

 

second), amber

 

 

 

 

 

 

 

 

RAID card

This topic provides information to help you locate the connectors on a RAID card installed on the riser card assembly 2.

Your server comes with a RAID card to provide advanced SATA/SAS hardware RAID functions to the server. For more information, refer to “Replacing the RAID card” on page 85.

Your server supports the following RAID cards:

ThinkServer RAID 500 Adapter (also known as ThinkServer 9240-8i RAID 0/1 Adapter)

ThinkServer RAID 700 Adapter (also known as ThinkServer 9260-8i SAS RAID Adapter)

ThinkServer RAID 710 Adapter (also known as 9270CV-8i RAID adapter)

30ThinkServer RD540 User Guide and Hardware Maintenance Manual

Page 44
Image 44
Lenovo RD540 manual Hot-swap hard-disk-drive status LEDs, RAID card