User Manual

Speed/Duplex:

Set the speed and duplex of the port. In speed, 10/100Mbps baud rate is available for Fast Ethernet, Gigabit module in port 25, 26. If the media is 1Gbps fiber, it is always 1000Mbps and the duplex is full only. If the media is TP, the Speed/Duplex is comprised of the combination of speed mode, 10/100/1000Mbps, and duplex mode, full duplex and half duplex. The following table summarized the function the media supports.

 

Media type

 

 

NWay

 

Speed

 

Duplex

 

 

 

 

 

 

 

 

 

 

 

 

 

 

100M TP

 

ON/OFF

 

10/100M

 

Full/Half

 

 

1000M TP

 

ON/OFF

 

10/100/1000M

 

Full for all, Half for 10/100

 

 

1000M Fiber

 

ON/OFF

 

1000M

 

Full

 

In Auto-negotiation mode, no default value. In Forced mode, default value depends on your setting.

Flow Control:

There are two modes to choose in flow control, including Symmetric and Asymmetric. If flow control is set Symmetric, both parties can send PAUSE frame to the transmitting device(s) if the receiving port is too busy to handle. When it is set Asymmetric, this will let the receiving port care the PAUSE frame from transmitting device(s), but it doesn’t send PAUSE frame. This is one-way flow control.

Default: Symmetric.

Publication date: June, 2005

Revision A1

52

Page 56
Image 56
LevelOne GSW-2690 user manual Media type NWay Speed Duplex