LG Electronics IP LDK-20 1.3 MJ4 Pin Assignment, 1.4 SW3 Functions and LED Indications

Models: IP LDK-20

1 80
Download 80 pages 48.41 Kb
Page 30
Image 30

IP LDK-20 Installation Manual

Board Installation

 

 

5-6

RESERVED

3.2.1.3 MJ4 Pin Assignment

MBUB

CONNECTOR

PIN NUMBER

NO

SIGNAL NAME

RJ45

 

1,2

Relay1-R, Relay1-T

 

 

3,4

Relay2-R, Relay2-T

 

 

5,6

EXT_PAGE-R, EXT_PAGE-T

 

 

7,8

Alarm-R, Alarm-T

3.2.1.4 SW3 Functions and LED Indications

SWITCH

FUNCTION

OFF

ON(DEFAULT)

3-1 Administration Programming Access

3-2 Command/Event Trace (The purpose of testing software)

3-3 SMDI (Simplified Message Desk Control –Voice Mail )

3-4 Database default on power up

Disable

Enable

SMDI ON

Disable

Enable

Disable

SMDI OFF

Enable

Before programming the system, switch 3-4 should be placed in the ON position and power cycled-OFF and –ON to initialize the system database to default. Once the database has been initialized, switch 3-4 should be placed in the OFF position to protect the database.

After putting the lithium battery switch (SW1) into ON to protect RAM/RTC data, install the option boards to the MBUB.

CAUTION

The DIP switch, SW1 should be turned ON to protect system data in case of a power failure.

The system will not function properly if the battery is incorrectly replaced. Replace only with the same or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer instructions.

The 4th pole (switch 4) of SW3 should be OFF to protect the features being programmed in Admin programming after the system power up and initialization.

LED INDICATIONS

LED

MEANING

LD1 (RED)

Periodic toggle – ON: 2 sec., OFF: 100m sec.

LD2 (RED)

Periodic toggle – ON: 2 sec., OFF: 100m sec.

LD3 (RED)

Timer, Flashing every 100msec

LD4 (RED)

LCD active updating, Flashing every 300msec

LD5 (GREEN)

The status of PLL for 32Mhz clock synchronization (ON : ACT, OFF : INACT)

LD6 (RED)

The status of Main SYSTEM Power

LED

 

STATUS

ON

OFF

LINE NO.

REMARK

LD7

RED

ERROR

IDLE

GREEN

IN-USE

 

 

LD8

RED

ERROR

IDLE

1

2

BRI

BRI

26

Page 30
Image 30
LG Electronics IP LDK-20 installation manual 1.3 MJ4 Pin Assignment, 1.4 SW3 Functions and LED Indications