IP LDK-20 Installation Manual

Troubleshooting

 

 

SECTION 7. TROUBLESHOOTING

PROBLEM

System power failure

System does not operate

DKTU does not operate

SLT does not operate

CO line operation

ISDN board does not operate

Noise on External Paging port

Distorted External

MOH

CAUSE / SYMPTOM

SOLUTION

Power short circuit in

Exchange the malfunctioning board for one in good working

some board(s)

 

condition.

LD6 LED light on the MBUB

Dust each board.

Check the PSU fuse.

is OFF or blinking

 

Replace the PSU with the appropriate type.

 

 

 

 

Power short circuit in

Check the connection of each board with MBUB.

some board(s)

 

Press the Reset button.

 

 

 

 

Check the PSU.

Bad board connection

Check the short circuit on MBUB or other boards.

 

 

 

 

Press the Reset button when the DIP switch (for database

System database broken

protection) is in the default position.

 

 

Bad extension circuit

Exchange the malfunctioning board for one in good working

 

 

 

 

condition.

Bad

connection

between

The connection between the system and the keyset must

the MBUB/DTIB and keyset

be repaired.

 

 

 

 

Check the connection between the line of SLIB and DTIB

 

 

 

 

on the MDF, and fix any mismatching.

The

limit

of

installation

Check the distance between the MBUB/DTIB and keyset.

distance

 

 

 

 

 

 

 

Bad keyset

 

 

Plug the keyset into another extension port that has been

 

 

 

 

verified as working.

 

 

 

 

If the keyset does not work, replace the keyset.

Bad MBUB or SLIB board

Exchange the board for one in good working condition.

Bad

connection

between

Check that the board connection between the lines of SLT

the MBUB/SLIB and SLT

and DKT on the MDF, and fix any mismatching.

ACNR Fail

 

 

Check the PRCPTU4, and CPCU4

Bad connection

 

Check the connection.

The position of switch

Check the switch for term and So/To position

Network problem

 

Check the Network.

Induced noise on the wire

Use a shielded cable as the connection wire between the

between the system and the

system and amplifier.

amplifier

 

 

A short shielded cable is recommended.

Excessive

input

level from

Decrease the output level of the external music source by

external music source

using the volume control on the music source.

76

Page 80
Image 80
LG Electronics installation manual IP LDK-20 Installation Manual Troubleshooting, Problem, Moh, Cause / Symptom Solution