Manuals
/
Lightwave Communications
/
Computer Equipment
/
Network Card
Lightwave Communications
manual Table Of Contents, iv LDT-5525
Models:
LDT-5525
1
6
56
56
Download
56 pages
22.8 Kb
3
4
5
6
7
8
9
10
<
>
Troubleshooting
Specification
Error codes
Warranty
Comments, Suggestions, and Problems
Parameter Setup
General Operating Procedures
Adjustments
Resolution
Temperature Controller LDT-5525
Page 6
Image 6
TABLE OF CONTENTS
iv
LDT-5525
Page 5
Page 7
Page 6
Image 6
Page 5
Page 7
Contents
Temperature Controller LDT-5525
User’s Guide
700199040701
Page
TABLE OF CONTENTS
Chapter 1 Introduction and Specifications
Chapter 2 Operation
Chapter 3 Maintenance and Troubleshooting
Appendix A Steinhart-Hart Equation
Appendix B Sensing Current and Thermistor Selection
AD590 Sensor LM335 Sensor One Point Calibration Method
Appendix C AD590 and LM335 Sensor Calibration
TABLE OF CONTENTS
Two Point Calibration Method
TABLE OF CONTENTS
iv LDT-5525
LIST OF FIGURES
LIST OF FIGURES
LIST OF FIGURES
vi LDT-5525
SAFETY AND WARRANTY INFORMATION
Safety Information and the Manual
General Safety Considerations
SAFETY SYMBOLS
Safety Marking Symbols
WARRANTY
Limitations
Returning an Instrument
Claims for Shipping Damage
WA R R A N T Y
x LDT-5525
Comments, Suggestions, and Problems
We look forward to serving you even better in the future
WA R R A N T Y
xii LDT-5525
INTRODUCTION AND SPECIFICATIONS
Product Overview
C H A P T E R
Available Options and Accessories
INTR ODUCTION AND SP ECIFI CATIONS
Specifications
Temperature Control
Output1
User Calibration
Measurement Display
General
6 LDT-5525
Specifications
INTR ODUCTION AND SP ECIFI CATIONS
C H A P T E R
Rack Mounting
AC Power Considerations
OPERATION
C H A P T E R
Power-Up Sequence
Introduction to the LDT-5525 Front Panel
Figure 2.1 LDT-5525 Front Panel
Adjustments
Display
Parameters
Parameter Setup
SENSOR CAL
Control Mode
Error Indicators
Output
SENSOR SELECT Switch
Back Panel Controls and Connections
Analog Output
TEC Connector
Table 2.1 SENSOR SELECT Switch Positions
Back Panel Controls and Connections
TEC Grounding Considerations
O P E R A T I O N
14 LDT-5525
General Operating Procedures
Temperature Mode Operation
Warm-Up and Environmental Considerations
Resistance Mode Operation
External Safety Switch Operation
Booster Operation
18 LDT-5525
General Operating Procedures
O P E R A T I O N
C H A P T E R
MAINTENANCE AND TROUBLESHOOTING
Calibration Overview
C H A P T E R
Warm Up
Recommended Equipment
Environmental Conditions
SPECIFICATION
Calibration Adjustments
Thermistor Calibration
AD590 Sensor Calibration
LM335 Sensor Calibration
ITE Current Calibration
Troubleshooting
Symptom
Causes and Corrective Actions
Unable to adjust output or
STEINHART-HART EQUATION
A P P E N D I X A
1/T = A + B * ln R Equation
Computer Program
30 LDT-5525
LDT-5525
32 LDT-5525
C H A P T E R A
SENSING CURRENT AND THERMISTOR SELECTION
Thermistor Range
A P P E N D I X B
Table B.2 10K Thermistor Temperature Range
TEMPERATURE RANGE
SENSING CURRENT
Selecting the Sensing Current
Temperature Resolution
Selecting and Using Thermistors
Table B.3 10K Thermistor Voltage vs. Resolution
generally a good choice for most laser diode applications where high stability is required near room temperatures. Similarly, 10 K thermistors are often a good choice for detector cooling applications where you want to operate at temperatures from -30 oC to room temperature
AD590 AND LM335 SENSOR CALIBRATION
AD590 Sensor
A P P E N D I X C
LM335 Sensor
Tn = v / 10mV / K - 273.15 - where Tn is in oC
One Point Calibration Method
Two Point Calibration Method
40 LDT-5525
C1n = U + V * C1 and C2n = V * C2
LDT-5525
42 LDT-5525
C H A P T E R C