No-beep error messages
| FRU/Action in Sequence |
|
|
No beep, | • Test the power source (battery pack and power |
and LCD is blank. | adapter). See “Testing the power system” on page 138. |
| • Make sure that every connector is connected tightly |
| and correctly. |
| • Reconnect the |
| • Test or replace the LED board. |
| • Test or replace the system board. |
|
|
No beep, | • Test the power source (battery pack and power |
and LCD is blank. | adapter). See “Testing the power system” on page 138. |
| • Reconnect the LCD connector |
| • Check the hard disk drive. |
| • Check the LCD inverter ID. |
| • Check the LCD cable. |
| • Test or replace the LCD inverter. |
| • Test or replace the LCD. |
| • Test or replace the system board. |
|
|
No beep, | • Reconnect the LCD connectors. |
and LCD is blank. But you can see POST | • Check the LCD inverter ID. |
on an external CRT. | • Check the LCD cable. |
| • Test or replace the LCD inverter. |
| • Test or replace the LCD. |
| • Test or replace the system board. |
|
|
No beep, | • Make sure that every connector is connected tightly |
and a blinking cursor shown on LCD | and correctly. |
during POST. | • Test or replace the system board. |
|
|
No beep during POST but system runs | • Test or replace the speaker. |
correctly. | • Test or replace the system board. |
|
|
Chapter 4: Troubleshooting | 143 |