Lincoln Electric C2.410 manual Deep Groove Welds Joint a Pass E6011T, Over E6011 Root Passes

Models: C2.410

1 44
Download 44 pages 9.82 Kb
Page 13
Image 13

Deep Groove Welds

Joint A

Pass 1

E6011T

1/8"

 

60°

 

2

 

1

 

Back gouge before￿

1/16"

welding final pass

Root passes - Joints A, B & C - 3/16 Fleetweld 35 (E6011), 175-180 Amps. AC at 6-9 in/min.

 

 

JOINT A

 

 

 

 

 

 

 

Plate Size – T (in.)

3/8

1/2

5/8

5/8

No. of Passes

2-3

2-3

2-3

4

 

 

 

 

 

 

Electrode/AWS Class

 

Jetweld 2/E6027

 

 

 

 

 

 

Diameter (in.)

3/16

7/32

 

1/4

7/32

 

 

 

 

 

 

Current (Amps)

280

340

 

375

340

Polarity

AC

AC

 

AC

AC

 

 

 

 

 

 

Ft. of Weld/Hr.(1)

21

19

 

14

14

Lbs. of Elec./Ft. of Weld(2)

.366

.4810

 

.795

.235

 

 

 

 

 

 

(1)Total for all passes. 100% operating factor.

(2)Plus .160 lbs. of 3/16” E6011/ft. of weld for each root pass.

Over E6011 Root Passes

Joint B

 

Joint C

 

5/16" & 3/8" Pass 1 — E6011 Passes 1 to 3 —

1/2" - 1" Pass 1 & 2 — E6011

E6011

9

 

 

 

 

2

 

8

T

 

7

 

1

 

T

 

 

 

4

1/8"

1/8"

 

5

 

 

6

 

 

 

60°

2 1 3

1/8" Root opening

 

 

 

JOINT B

 

JOINT C

Plate Size – T (in.)

5/16

3/8

1/2

3/4

1

3/4

1

 

1-1/2

No. of Passes

2

2-3

3

3-6

3-10

4-5

4-7

 

4-9

Electrode/AWS Class

 

 

 

Jetweld 2/E6027

 

 

 

Diameter (in.)

5/32

 

5/32

1/4

1/4

1/4

 

1/4

 

 

 

 

 

 

 

 

 

 

 

 

 

Current (Amps)

220

 

220

390

390

390

 

390

 

 

Polarity

AC

 

AC

AC

AC

AC

 

AC

 

 

 

 

 

 

 

 

 

 

 

 

Ft. of Weld/Hr.(1)

21

 

16

14

8.2

5.3

9.0

6.2

 

4.1

Lbs. of Elec./Ft. of

.142

 

.284

.354

1.47

2.94

.728

1.45

 

3.04

Weld(2)

 

 

 

 

 

 

 

 

 

 

(1)Total for all passes. 100% operating factor.

(2)Plus .160 lbs. of 3/16” E6011/ft. of weld for each root pass.

-13-