Lincoln Electric C2.410 manual Stick Electrode Typical Operating Procedures, Out-of-Position Group

Models: C2.410

1 44
Download 44 pages 9.82 Kb
Page 36
Image 36

Minimum Preheat and Interpass Temperature(1) Continued

For stick electrode welding only

Based on AWS Specification D1.1

Notes

(1)Welding shall not be done when ambient temp. is lower than 0ºF. Parts on which metal is being deposited shall be at or above the specified temperature for a distance equal to the thickness of the part being welded, but not less than 3”, in all directions from the point of welding. Preheat and interpass temperature must be sufficient to prevent cracking. Temperature above the minimum may be required for highly restrained welds. For ASTM A709 Grade 70W and ASTM A852 Grade 70, the maximum preheat and interpass tem- perature shall not exceed 400ºF for thicknesses thru 1-1/2”, and 450ºF for greater thicknesses.

(2)When the base metal temperature is below 32ºF, preheat to at least 70ºF and maintain this minimum temperature during welding.

Stick Electrode Typical Operating Procedures

“Out-of-Position” Group

All-purpose stick electrodes for general purpose fabrication and maintenance weld- ing. Capable of x-ray quality welds out-of-position. Particularly good for vertical and overhead. Deep penetration with maximum admixture. Light slag and flat beads with distinctive ripples.

 

 

 

 

 

 

 

 

Sizes & Current Ranges (Amps)

 

 

 

Product

AWS

Electrode

 

 

 

 

 

 

 

 

 

 

 

Name

Class

 

Polarity

3/32”

1/8”

5/32”

3/16”

7/32”

 

1/4”

Fleetweld® 5P

 

E6010

 

 

DC+

40-70

75-130

90-175

 

140-225

200-275

220-325

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fleetweld 5P+

 

E6010

 

 

DC+

40-70

65-130

90-175

 

140-225

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fleetweld 35

 

E6011

 

 

AC

50-85

75-120

90-160

 

120-200

150-260

190-300

 

 

 

 

 

DC±

40-75

70-110

80-145

 

110-180

135-235

170-270

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fleetweld 180

 

E6011

 

 

AC

40-90

60-120

115-150

 

---

---

---

 

 

 

 

 

 

DC±

40-80

55-110

105-135

 

---

---

---

 

Fleetweld 22

 

E6022

 

 

DC+

---

110-150

150-180

 

---

---

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

For Welding High Tensile Pipe

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shield-Arc®85

E7010-A1

DC+

50-90

75-130

90-175

 

140-225

---

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shield-Arc HYP+

E7010-P1

DC+

---

75-130

90-185

 

140-225

---

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shield-Arc 70+

E8010-G

DC+

---

75-130

90-185

 

140-225

---

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shield-Arc 80

E8010-G

DC+

---

75-130

90-185

 

140-225

160-250

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Shield-Arc 90

E9010-G

DC+

---

75-130

90-185

140-225

---

 

---

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPTIONAL SUPPLEMENTAL

 

 

 

 

 

 

 

 

 

 

 

 

DESIGNATOR

 

 

 

 

 

 

 

 

 

 

 

7018

H4R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWS CLASS (OR NAME)

LOOK FOR LINCOLN'S

 

 

 

 

 

 

 

ON EACH ELECTRODE SYMBOL OF DEPENDABILITY

 

 

 

 

-36-

Page 36
Image 36