Lincoln Electric LF-72/74 service manual Analog Miller Control Cable Adapter K2335-1, Pin Function

Models: LF-72/74

1 119
Download 119 pages 24.05 Kb
Page 14
Image 14

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-8

NOTES

A-8

 

 

 

ANALOG

MILLER CONTROL

CABLE

ADAPTER K2335-1

This Lincoln Electric wire feeder may be mounted to a limit- ed number of Miller Electric power sources. The Miller power source must have the amphenol pin definition shown in the table below for proper operation of the wire feeder.

Operation of Lincoln wire feeders on Miller power sources may result in lack of high speeds or reduce pull force on high wire feed speeds. Maximum wire feed speed for the LF-72 operating on a Miller power source is approximately 720ipm. Be sure the Miller power source provides 24 VAC to the wire feeder and has overcurrent protection of no more than 15 amps. The power source must not exceed 113VDC peak.

POWER SOURCE

 

WIRE FEEDER

I J

 

K A

B

 

B

A

K J I

 

 

 

 

H G N

 

ML

 

C

 

C D

L

MN G H

D

 

F

 

E

 

 

 

 

E

F

 

 

 

 

 

 

 

 

 

 

MILLER POWER SOURCE

 

LINCOLN WIRE FEEDER

Pin

Function

Pin

Function

 

 

 

 

A

24 VAC to feeder

I

42 VAC feeder

 

 

D

Welding Output Control

B

Welding Output Control

C

Welding Output Control

C

+10VDC to feeder for remote control

E

Remote Voltage Control ("+" supply, from

 

 

 

power source)

D

Remote control common

G

Remote Voltage Control ("-" supply, from

 

 

 

power source)

E

0-10VDC from feeder for remote control.

F

Remote Voltage Control (control signal from

 

 

 

feeder or remote.)

F

Current feedback to feeder.

J

Reserved for future use.

 

Scaled 0-10V. 1 V = 100 amps.

 

 

 

Referenced to pin D.

 

 

G

24 VAC common.

K

42 VAC to feeder

H

Arc Voltage feedback to feeder.

L

Reserved for future use.

 

Scaled 0-10V. 1 V = 10 Arc volts.

 

 

 

Referenced to pin D.

 

 

I

 

 

 

J

 

 

 

K

 

 

 

L

 

 

 

M

 

 

 

N

 

N

Electrode voltage to power source (67)

 

 

 

 

Miller is a registered trademark not owned or licensed by The Lincoln Electric Company.

LF-72/74

Page 14
Image 14
Lincoln Electric LF-72/74 Analog Miller Control Cable Adapter K2335-1, Miller Power Source Lincoln Wire Feeder