AA-8

INSTALLATION

AA-8

 

 

 

ANALOG

MILLER CONTROL

CABLE

ADAPTER K2335-1

This Lincoln Electric wire feeder may be mounted to a limited number of Miller Electric power sources. The Miller power source must have the circular connector pin definition shown in the table below for proper oper- ation of the wire feeder. Be sure the Miller power source provides 24 VAC to the wire feeder and has overcurrent protection of no more than 15 amps. The power source must not exceed 113VDC peak.

Operation of Lincoln wire feeders on Miller power sources may result in lack of high wire feed speeds or reduced pull force at high wire feed speeds. Approximate maximum WFS for Lincoln wire feeders operating with 24 VAC:

 

 

LF-72

 

 

 

 

 

720 ipm

 

 

 

 

 

 

 

LF-74

 

 

 

 

 

720 ipm

 

 

 

 

 

 

 

LF-74, extra torque

360 ipm

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

POWER SOURCE

 

 

 

WIRE FEEDER

 

 

 

I J

 

K A

B

 

 

 

 

B

A

K J I

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H G N

 

ML

 

C

 

 

 

 

C D

L

MN G H

 

 

 

 

D

 

 

 

 

 

 

 

 

F

 

E

 

 

 

 

 

 

 

E

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MILLER POWER SOURCE

 

 

 

LINCOLN WIRE FEEDER

Pin

Function

 

 

 

 

 

 

Pin

 

 

 

Function

 

 

 

 

 

 

 

 

 

 

 

 

A

24 VAC to feeder

 

 

 

 

 

 

I

42 VAC feeder

 

 

 

 

 

 

 

 

 

 

D

Welding Output Control

B

Welding Output Control

 

 

 

 

 

 

C

Welding Output Control

C

+10VDC to feeder for remote control

 

E

Remote Voltage Control ("+" supply, from

 

 

 

 

 

 

 

 

 

 

 

power source)

D

Remote control common

 

 

 

 

 

 

G

Remote Voltage Control ("-" supply, from

 

 

 

 

 

 

 

 

 

 

 

power source)

E

0-10VDC from feeder for remote control.

F

Remote Voltage Control (control signal from

 

 

 

 

 

 

 

 

 

 

 

feeder or remote.)

F

Current feedback to feeder.

 

 

 

 

J

Reserved for future use.

 

Scaled 0-10V. 1 V = 100 amps.

 

 

 

 

 

 

 

 

Referenced to pin D.

 

 

 

 

 

 

 

 

 

 

 

 

G

24 VAC common.

 

 

 

 

 

 

K

42 VAC to feeder

H

Arc Voltage feedback to feeder.

 

L

Reserved for future use.

 

Scaled 0-10V. 1 V = 10 Arc volts.

 

 

 

 

 

 

 

 

Referenced to pin D.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N

 

 

 

 

 

 

 

 

 

N

Electrode voltage to power source (67)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Miller is a registered trademark not owned or licensed by The Lincoln Electric Company.