Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

AA-7

INSTALLATIONAA-7

ANALOG CONTROL CABLE

CONTROL CABLE CONNECTIONS

K1797-xx

The control cable connecting the wire feeder to the power source is specially made for the welding envi- ronment.

The wire feeder power requires overcurrent protection. Connect the wire feeder only to power sources with overcurrent protection of no more than 15 amps.

POWER SOURCE

WIRE FEEDER

H

I

J

KAB

C

C

B A

KJ I

H

 

N

L

L

N

 

GF

ME D

 

DE

MFG

PIN

FUNCTION

LEAD#

 

 

 

A

Reserved

-------

B

Reserved

-------

C

Welding Output Control

2

 

(trigger from feeder)

 

D

Welding Output Control

4

 

(trigger from feeder)

 

E

Remote Voltage Control

77

 

(“+” supply from feeder or remote)

 

F

Remote Voltage Control

76

 

(control signal from feeder or remote)

 

G

Remote Voltage Control

75

 

(“-” supply from feeder or remote)

 

H

Reserved

 

I

42 VAC

41

J

Reserved

 

 

 

 

K

42 VAC

42

L

Reserved

 

 

 

 

M

Reserved

-------

N

Electrode voltage from feeder

67

 

 

 

Do not use more than 100 ft (30.5 m) of control cable between the wire feeder and power source.

LF-72/74

Page 49
Image 49
Lincoln Electric LF-72/74 service manual INSTALLATIONAA-7, K1797-xx