TROUBLESHOOTING & REPAIR

F-5

LF-72/74

Observe Safety Guidelines detailed in the beginning of this manual.

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

FUNCTION PROBLEMS (Continued)

 

 

No shielding gas.

1. No gas supply, or gas supply

1.

Verify cylinder is not empty and

 

 

interrupted.

 

is turned on.

 

 

2. Solenoid not functioning.

Check the hose for cuts or kinks.

 

 

 

Make sure it is not crushed.

 

 

 

Verify the hose is connected to the

 

 

 

gun bushing or welding gun.

 

 

 

2.

Perform the GAS SOLENOID

 

 

 

 

TEST.

 

 

 

 

 

 

Variable or hunting arc.

1. Bad contact tip

1.

Check for proper size contact

 

 

2. Possible loose connection in

 

tip. Make sure tip is not worn,

 

 

current carrying cables.

 

and is free of spatter.

 

 

3. Set up not correct.

2.

Clean and tighten all electrode

 

 

4. Problem with shielding gas.

 

and work connections. Verify

 

 

 

 

the gun bushing is tightly

 

 

 

 

mounted to the wire drive.

 

 

 

 

Verify the gun is tightly mounted

 

 

 

 

to the gun bushing.

 

 

 

3.

Verify the proper polarity is

 

 

 

 

being used for the weld proce-

 

 

 

 

dure. Make sure the proper

 

 

 

 

electrode stick-out is being

 

 

 

 

maintained.

 

 

 

4.

Check the gas flow rate and

 

 

 

 

mixture.

 

 

 

5.

Control board may be faulty.

 

 

 

 

 

 

When the trigger is pulled, the

1. Possible bad gun or faulty con-

1.

Check all electrode and work

 

drive rolls spin but no arc voltage

nections in the heavy current

 

connections. Verify the the gun

 

 

carrying leads.

 

bushing is tight to the wire

 

 

2. Possible faulty control cable.

 

drive. Verify gun is tightly

 

 

 

mounted to the bushing.

 

 

 

 

 

 

3. Possible defective power

2.

Check the control cable and

 

 

source.

 

 

 

connectors for continuity, cuts,

 

 

 

 

 

 

 

 

or broken pins.

 

 

 

3.

Verify the power source is oper-

 

 

 

 

ating properly.

 

 

 

 

 

 

The arc burns back to the tip.

1. If timer kit is installed, reduce

 

 

 

 

the amount of burnback time.

 

 

 

The gas continues to flow for a

2. If the timer kit is installed,

 

 

 

reduce the amount of post flow

 

 

 

long time after the weld.

 

 

 

time.

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department at 1-888-935-3877 for electrical troubleshooting assistance before you proceed.