Lincoln Electric LF-72/74 INSTALLATIONA-7, Analog Control Cable, Control Cable Connections

Models: LF-72/74

1 119
Download 119 pages 24.05 Kb
Page 13
Image 13

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-7

INSTALLATIONA-7

ANALOG CONTROL CABLE

CONTROL CABLE CONNECTIONS

All control cables can be connected end to end to extend their length.

The control cable connecting the wire feeder to the power source is specially made for the welding envi- ronment.

The wire feeder power requires overcurrent protection. Connect the wire feeder only to power sources with overcurrent protection of no more than 15 amps.

POWER SOURCE

WIRE FEEDER

J

A

A

J

H I N

KL BC

CB L

KNI H

GF

ME D

DE

MFG

PIN

FUNCTION

LEAD#

 

 

 

A

Unused

-------

B

Reserved

-------

C

Welding Output Control

2

 

(trigger from feeder)

 

D

Welding Output Control

4

 

(trigger from feeder)

 

E

Remote Voltage Control

77

 

(“+” supply from feeder or remote)

 

F

Remote Voltage Control

76

 

(control signal from feeder or remote)

 

G

Remote Voltage Control

75

 

(“-” supply from feeder or remote)

 

H

Reserved

 

I

42 VAC

41

J

Reserve for Future Use.

 

 

 

 

K

42 VAC

42

L

Reserve for Future Use.

 

 

 

 

M

Unused

-------

N

Electrode voltage from feeder

67

 

 

 

Do not use more than 100 ft (30.5 m) of control cable between the wire feeder and power source.

LF-72/74

Page 13
Image 13
Lincoln Electric LF-72/74 service manual INSTALLATIONA-7, Analog Control Cable, Control Cable Connections