Return to Section TOC

Return to Master TOC

A-4

A-4

INSTALLATION

TECHNICAL SPECIFICATIONS - IDEALARC R3R-500

INPUT - THREE PHASE ONLY

Standard Voltage

Input Current @ Rated Output

230V

88A

460V

44A

Return to Section TOC

Return to Master TOC

Duty Cycle

100%

60%

35%

RATED OUTPUT

Amps

600

500

375

OUTPUT

Volts at Rated Amps

44

40

35

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Current Range

Maximum Open Circuit Voltage

75 to 625 Amps

67 VDC

 

RECOMMENDED INPUT WIRE AND FUSE

SIZES AT 60% DUTY CYCLE

 

 

 

 

 

 

 

 

Input Wire Size

Ground Wire Size

 

 

Input Voltage /

 

Fuse

Input Ampere

 

Type 75°C

Type 75°C

 

 

Frequency

(Super Lag)

Rating on

 

Copper Wire in

Copper Ground

 

 

 

or Breaker Size

Nameplate

 

Conduit

Wire in Conduit

 

 

Volts/Hz

 

 

 

 

 

AWG (IEC) Sizes

AWG (IEC) Sizes

 

230/60

150

88

 

 

4 (25 mm2)

6 (16 mm2)

 

460/60

70

44

 

 

8 (10 mm2)

8 (10 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL

DIMENSIONS

 

 

 

 

Height

 

Width

 

 

 

Depth

 

Weight

 

 

27.50 in.

 

22.25 in.

 

 

33.10 in.

 

446 lbs.

 

 

(700 mm)

 

(565 mm)

 

 

(840 mm)

 

(202 kg)

 

 

 

 

 

 

 

 

 

 

 

 

IDEALARC R3R

Page 10
Image 10
Lincoln Electric R3R-300 service manual Technical Specifications Idealarc R3R-500