F-6

 

 

 

 

 

 

 

 

 

F-6

 

TROUBLESHOOTING & REPAIR

 

 

 

 

 

 

Observe Safety Guidelines

 

 

 

 

TROUBLESHOOTING GUIDE

 

detailed in the beginning of this manual.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

 

 

 

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

 

The machine has minimum (or very

1. Make certain the three-phase

1.

Check the Output Control (R1)

 

low) welding output and no con-

input voltage is correct and

 

and associated wiring. See the

 

trol.

matches the rating plate and

 

Wiring Diagram.

 

 

 

 

 

the reconnect panel.

 

2. Check the Output Control

 

 

 

 

 

 

 

 

2. Make certain the Dial Control

 

Switch

(S2)

and

associated

 

 

Switch (SW3) is in the correct

 

wiring.

See

the

Wiring

 

 

position.

(Not present on R3R

 

Diagram.

 

 

 

 

 

 

300).

 

 

 

3. Perform the Main Transformer

 

 

 

 

 

 

 

 

3. If the remote control is being

 

Test.

 

 

 

 

 

 

 

used, set the Output

Control

4.

Perform

the

SCR/Diode

 

 

Switch (SW2) to the Machine or

 

 

 

Rectifier Bridge Test.

 

 

 

 

Local position and control the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

weld output with the machine

5. If the Pocket Amptrol is not

 

 

Output Control (R1).

If the

 

functioning

properly,

perform

 

 

problem is resolved, check the

 

the Pocket

Amptrol

Circuit

 

 

remote control unit and associ-

 

Test.

 

 

 

 

 

 

 

ated cable leads. If the Pocket

6.

The control

board

may be

 

 

Amptrol option is being used,

 

 

 

faulty. Replace.

 

 

 

 

 

the Pocket Amptrol circuit may

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

be faulty.

 

 

 

 

 

 

 

 

 

 

 

 

4. Make sure the remote control

 

 

 

 

 

 

 

 

 

leads (#75, #76, #77) are not

 

 

 

 

 

 

 

 

 

grounded or shorted to the

 

 

 

 

 

 

 

 

 

positive

or negative

welding

 

 

 

 

 

 

 

 

 

output.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

The input contactor operates - the

1. Make certain the output control

1.

Check for loose or faulty con-

 

fan runs - the pilot light is on - but

switch (SW2) is in the Machine

 

nections on the heavy current

 

the machine has no welding out-

or Local position.

If the prob-

 

carrying leads between the out-

 

put. The open circuit voltage is not

lem is resolved, check the

 

put terminals, the shunt, the

 

present at the output terminals.

remote control and associated

 

choke

and

the

SRC/Diode

 

 

circuitry.

See

the

Wiring

 

Bridge.

See

the

Wiring

 

 

Diagram.

 

 

 

 

Diagram.

 

 

 

 

 

 

 

 

 

 

2.

Perform

the

SCR/Diode

 

 

 

 

 

 

 

Rectifier Bridge Test.

 

 

 

 

 

 

 

 

3. Perform the Main Transformer

 

 

 

 

 

 

 

Test.

 

 

 

 

 

 

 

 

 

 

 

4. The control board may be

 

 

 

 

 

 

 

faulty. Replace.

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.