B-3

B-3

OPERATION

Return to Section TOC

Return to Section TOC

TOC

Return to Master TOC

Return to Master TOC

TOC

GENERAL DESCRIPTION

The Idealarc R3R is an SCR controlled constant cur- rent DC output power source for welding and cutting. The R3R-300 uses a single range potentiometer con- trol. The R3R-400 and R3R-500 have separate low and high range controls. The welder’s unique combi- nation of 3 phase transformer, SCR/Diode bridge rec- tifier, arc control choke, and solid state control system deliver outstanding arc characteristics. For stick weld- ing, an Arc Force Control enables the Idealarc-R3R to create a soft welding arc for critical applications or a forceful driving arc for heavy duty applications.

RECOMMENDED PROCESSES

The Idealarc R3R is recomended for stick and DC TIG welding and air/carbon arc gouging.

DESIGN FEATURES AND ADVANTAGES

Input line voltage compensation keeps output con- stant for fluctuations of ± 10%.

Hinged front control panel provides easy access to printed circuit boards and other control circuitry.

Fully enclosed fan motor with permanently lubri- cated, sealed ball bearings needs no maintenance.

Fully recessed control panel protects controls and minimizes accidental contact.

Recessed output terminals reduces chance of acci- dental contact.

Low profile case permits installation under a work- bench.

Removable rear access panel provides easy access to input contactor and input lead connections.

Removable case sides provide easy access for ser- vice or inspection, even when machines are stacked.

Dripproof enclosure design permits outdoor operation.

Double-dipped transformer, SCR bridge, and choke resist corrosion.

WELDING CAPABILITY

The Idealarc R3R has the following duty cycle ratings. If the duty cycle is exceeded, a thermal protector will shut off the machine output until it cools to normal operating temperature. The amber thermal protection indicator light will turn on until the machine cools.

Return to Section

Return to Section TOC

Return to Master

Return to Master TOC

60% Duty Cycle*

Amps

Volts

R3R-300

300

32

R3R-400

400

36

R3R-500

500

40

*Based on a 10 minute time period. For example, a 60% duty cycle means 6 minutes on and 4 minutes off.

IDEALARC R3R

Page 19
Image 19
Lincoln Electric R3R-500, R3R-300 Operation, General Description, Recommended Processes, Design Features and Advantages