F-62

F-62

TROUBLESHOOTING & REPAIR

RETEST AFTER REPAIR (R3R 400)

Retest a machine:

If it is rejected under test for any reason that requires you to remove any mechanical part which could affect the machine’s electrical characteristics. OR

If you repair or replace any electrical components.

INPUT IDLE AMPS AND WATTS

Input Volts/Phase/Hertz

Maximum Idle Amps

Maximum Idle KW

200/3/60

9.5

1.04

208/3/60

9.2

1.04

230/3/60

8.3

1.04

380/3/60

5.0

1.04

440/3/60

4.3

1.04

460/3/60

4.1

1.04

550/3/60

3.4

1.04

575/3/60

3.3

1.04

200/3/50

18.6

1.15

220/3/50

17.0

1.15

230/3/50

16.3

1.15

380/3/50

9.8

1.15

400/3/50

9.3

1.15

415/3/50

9.0

1.15

440/3/50

8.5

1.15

500/3/50

7.5

1.15

550/3/50

6.8

1.15

 

 

 

OPEN CIRCUIT VOLTAGES

 

Test Points

Input Hertz

Open Circuit Volts

 

 

Welding Output Terminals

60

63/69VDC

 

Welding Output Terminals

50

61/66VDC

 

 

 

 

 

WELDING OUTPUT LOAD TEST

 

Output Control Settings

Amps

Volts

 

 

Dial Selector at “A”

40

20VDC (Maximum)

 

Minimum

 

 

 

 

Dial Selector at “B”

500

43 to 47 VDC

 

Maximum

 

 

 

 

 

 

 

 

IDEALARC R3R

Page 96
Image 96
Lincoln Electric R3R-300, R3R-500 service manual Welding Output Terminals 63/69VDC 61/66VDC