TROUBLESHOOTING & REPAIR | ||||||
Observe Safety Guidelines |
|
|
|
| TROUBLESHOOTING GUIDE | |
detailed in the beginning of this manual. |
|
|
|
|
| |
|
|
|
| |||
PROBLEMS | POSSIBLE AREAS OF |
| RECOMMENDED | |||
(SYMPTOMS) | MISADJUSTMENT(S) |
| COURSE OF ACTION | |||
|
|
|
|
|
| |
|
| OUTPUT PROBLEMS |
|
|
| |
The output terminals are always | 1. | This is a normal condition. The |
|
| ||
electrically “hot.” |
| open circuit voltage should be |
|
| ||
|
| approximately 67VDC. | The |
|
| |
|
| open circuit voltage may vary |
|
| ||
|
| with the input line voltage. |
|
|
| |
|
|
|
|
| ||
The machine welds but reduces to | 1. | Operating the machine beyond | 1. | Check the output shunt for | ||
a low output under load and |
| the current rating will cause the |
| loose or faulty connections. | ||
remains there until the load is |
| overload protection | circuit | on | 2. | The output shunt may be faulty. |
removed and the arc |
| the control board | to phase- | |||
|
| Replace. | ||||
|
| back the machine to a low out- |
| |||
|
|
|
| |||
|
| put. |
|
| 3. | The control board may be faulty. |
|
|
|
|
|
| Replace. |
|
|
|
| |||
The machine shuts off even when | 1. Make sure the fan motor and | 1. | Perform the SCR/Diode | |||
not under load or makes excessive |
| blades are operating properly. |
| Rectifier Bridge Test. | ||
noise like it is loaded. |
|
|
|
| 2. | Perform the Main Transformer |
|
|
|
|
| ||
|
|
|
|
|
| Test. |
|
|
|
|
| 3. | Check the latching resistor R3. |
|
|
|
|
|
| Normal resistance is 40 ohms. |
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, con- tact the Lincoln Electric Service Department for electrical troubleshooting assistance before you proceed. Call