Lincoln Electric R3R-500, R3R-300 service manual Technical Specifications Idealarc R3R-400

Models: R3R-500 R3R-300

1 108
Download 108 pages 14.61 Kb
Page 9
Image 9

Return to Section TOC

Return to Master TOC

A-3

A-3

INSTALLATION

TECHNICAL SPECIFICATIONS - IDEALARC R3R-400

INPUT - THREE PHASE ONLY

Standard Voltage

Input Current @ Rated Output

230V

74A

460V

37A

Return to Section TOC

Return to Master TOC

Duty Cycle

100%

60%

35%

RATED OUTPUT

Amps

300

400

500

OUTPUT

Volts at Rated Amps

32

36

40

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Current Range

Maximum Open Circuit Voltage

60 to 500 Amps

67 VDC

 

RECOMMENDED INPUT WIRE AND FUSE

SIZES AT 60% DUTY CYCLE

 

 

 

 

 

 

 

 

Input Wire Size

Ground Wire Size

 

 

Input Voltage /

 

Fuse

Input Ampere

 

Type 75°C

Type 75°C

 

 

Frequency

(Super Lag)

Rating on

 

Copper Wire in

Copper Ground

 

 

 

or Breaker Size

Nameplate

 

Conduit

Wire in Conduit

 

 

Volts/Hz

 

 

 

 

 

AWG (IEC) Sizes

AWG (IEC) Sizes

 

230/60

125

74

 

 

6 (16 mm2)

6 (16 mm2)

 

460/60

60

37

 

 

10 (6 mm2)

10 (6 mm2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

PHYSICAL

DIMENSIONS

 

 

 

 

Height

 

Width

 

 

 

Depth

 

Weight

 

 

27.50 in.

 

22.25 in.

 

 

33.10 in.

 

402 lbs.

 

 

(700 mm)

 

(565 mm)

 

 

(840 mm)

 

(182 kg)

 

 

 

 

 

 

 

 

 

 

 

 

IDEALARC R3R