F-49

TROUBLESHOOTING AND REPAIR

F-49

 

 

 

OUTPUT CONTACTOR REPLACEMENT

WARNING

Service and repair should only be performed by Lincoln Electric factory trained personnel. Unauthorized repairs performed on this equipment may result in danger to the technician or machine operator and will invalidate your factory warranty. For your safety and to avoid electrical shock please observe all safety notes and precautions detailed throughout this manual.

If for any reason you do not understand the test procedures or are unable to perform the test/repairs safely, contact the Lincoln Electric service department for technical troubleshooting assistance before you proceed. Call 1-888-935- 3877.

DESCRIPTION

The following procedure will aid the technician in removing the Output Contactor for repair or replacement.

MATERIALS NEEDED

7/16” Wrench

5/16” Nutdriver

POWER MIG® 215