TROUBLESHOOTING AND REPAIR |
ABNORMAL OPEN CIRCUIT VOLTAGE
OUTPUT CAPACITOR BANK NOT FUNCTIONING (MAX TAP “G”)
0 Volts
20.0 V | 5 ms |
SCOPE SETTINGS
This is NOT a typical DC output voltage |
|
| ||
waveform. The output | capacitors | are | Volts/Div | 20V/Div |
not functioning. Note the lack of “filter- |
|
| ||
ing” in the output waveform. The output | Horizontal Sweep | 5 ms/Div | ||
capacitor bank was disconnected. Each |
|
| ||
vertical division represents 20 volts and | Coupling | DC | ||
each horizontal division represents 5 |
|
| ||
milliseconds in time. |
|
| Trigger | Internal |
NOTE: Scope probes | connected | at |
|
|
machine output | terminals: (+) |
|
| |
probe to electrode, |
|
| ||
work. |
|
|
|
|
|
|
|
|
|