TROUBLESHOOTING AND REPAIR

F-26

ABNORMAL OPEN CIRCUIT VOLTAGE

OUTPUT CAPACITOR BANK NOT FUNCTIONING (MAX TAP “G”)

0 Volts

20.0 V

5 ms

SCOPE SETTINGS

This is NOT a typical DC output voltage

 

 

waveform. The output

capacitors

are

Volts/Div

20V/Div

not functioning. Note the lack of “filter-

 

 

ing” in the output waveform. The output

Horizontal Sweep

5 ms/Div

capacitor bank was disconnected. Each

 

 

vertical division represents 20 volts and

Coupling

DC

each horizontal division represents 5

 

 

milliseconds in time.

 

 

Trigger

Internal

NOTE: Scope probes

connected

at

 

 

machine output

terminals: (+)

 

 

probe to electrode, (-) probe to

 

 

work.

 

 

 

 

 

 

 

 

 