Lochinvar 151 Z Flex, Model, FasNSeal, Saf-TVent, Z-Vent, Stainlesssteelairintake/ventconnections

Models: 151

1 76
Download 76 pages 1.76 Kb
Page 21
Image 21
ProTech

 

 

 

 

 

 

 

Installation & Operation Manual

3 General venting (continued)

 

 

 

 

 

Table 3B Approved Stainless Steel Terminations and Adapters

 

 

 

 

 

 

 

ProTech

 

Heat Fab

 

 

Z Flex

 

Model

 

FasNSeal

 

Saf-T Vent

 

 

Z-Vent

 

 

Flue

Intake

 

Intermediate

Flue

Intake

 

Flue

Intake Air

 

 

 

 

 

**Adapter

Air

**Adapter

Air

**Adapter

 

 

Termination

Termination

 

Adapter

Termination

Termination

 

Termination

Termination

151 - 200

300715

FSBS3

303889

KB80210

9353BUREZ-1*

9392

9314TERM

2SVSLA03

2SVSTP03

2SVSTEX0390

 

 

FSRC3(R.C)

 

 

 

5300CI

 

 

2SVSRCX03

 

286-601

F303759

FSBS4

FSAIH04

KB285600

9454BUREZ-1*

9492

9414TERM

2SVSLA04

2SVSTP04

2SVSTEX0490

 

 

FSRC4(R.C)

303888

 

 

5400CI

 

 

2SVSRCX04

 

701-801

F303759

 

FSAIH04

 

 

 

 

 

 

 

(Intake

FSBS6

 

 

 

 

 

 

 

303888

 

 

 

 

 

 

 

 

Only)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*= This adapter must be used in addition to the water heater adapter for Saf-T vent pipe as shown in FIG. 3-12, unless approved vent other than standard diameter is used. Consult a Heat Fab representative for questions.

**The stainless steel venting option is only available in 3" vent diameters.

Table 3C Stainless Steel Vent Termination Kit(s)
Model
Kit Number

701 - 801

KIT3137

Stainlesssteelairintake/ventconnections

1.Combustion Air Intake Connector (FIG.’s 3-12 thru 3-14) - Used to provide combustion air directly to the unit from outdoors. A fitting is provided on the unit for final connection. Combustion air piping must be supported per guidelines listed in the National Mechanical Code, Section 305, Table 305.4 or as local codes dictate.

2.Vent Connector (FIG.’s 3-12 thru 3-14) - Used to provide a passageway for conveying combustion gases to the outside. A transition fitting is provided on the unit for final connection. Vent piping must be supported per the National Building Code, Section 305, Table 305.4 or as local codes dictate.

Figure 3-12Near Water Heater Stainless Steel Venting Models 151 - 200

VENT

3" S.S. ADAPTER

3" S.S. INTERMEDIATE (FOR SAF-T VENT ONLY)

Heat Fab 21 Z Flex

Page 21
Image 21