Lochinvar 399 operation manual Ratings, Knight XL Boiler I=B=R Rating, Other Specifications, Notes

Models: 399

1 76
Download 76 pages 58.86 Kb
Page 7
Image 7
Ratings

Ratings

Knight XL Boiler

I=B=R Rating

 

 

Input

 

Net

Model Number

 

Gross

I=B=R

 

MBH

 

Ratings

 

 

Output

Note: Change “N” to

 

(Note 4)

MBH

Water,

 

 

MBH

“L” for L.P. gas models.

 

 

 

 

 

 

 

 

Min

 

Max

(Note 1)

(Note 2)

 

 

 

 

 

 

KBN399

80

 

399

373

324

 

 

 

 

 

 

KBN500

100

 

500

467

406

 

 

 

 

 

 

KBN600

120

 

600

567

493

 

 

 

 

 

 

KBN700

140

 

700

660

574

 

 

 

 

 

 

KBN800

160

 

800

752

654

 

 

 

 

 

 

Installation & Operation Manual

Other Specifications

Boiler

 

 

Air

Vent

Water

Water

Gas

 

 

Content

Connections

Connections

Size

Size

Gallons

 

 

 

 

 

 

 

 

(Note 3)

 

 

 

 

 

3.4

1-1/2"

1"

4"

4"

 

 

 

 

 

4.2

1-1/2"

1"

4"

4"

 

 

 

 

 

4.2

2"

1"

4"

4"

 

 

 

 

 

5.0

2"

1"

4"

6"

 

 

 

 

 

5.7

2"

1"

4"

6"

 

 

 

 

 

NOTICE Maximum allowed working pressure is located on the rating plate.

Notes:

1.The ratings are based on standard test procedures prescribed by the United States Department of Energy.

2.Net I=B=R ratings are based on net installed radiation of sufficient quantity for the requirements of the building and

nothing need be added for normal piping and pickup. Ratings are based on a piping and pickup allowance of 1.15.

3. Knight XL boilers require special gas venting. Use only the vent materials and methods specified in the Knight XL Installation and Operation Manual.

4.Standard Knight XL boilers are equipped to operate from sea level to 4,500 feet only with no adjustments. The boiler will de-rate by 4% for each 1,000 feet above sea level up to 4,500 feet.

5.High altitude Knight XL boilers are equipped to operate from 3,000 to 12,000 feet only with no field adjustments. The boiler will de-rate by 2% for each 1,000 feet above 3,000 feet. High altitude models are manufactured with a

different control module for altitude operation, but the Figure A High Altitude Label Location operation given in this manual remains the same as the

standard boilers. A high altitude label (as shown in FIG. A) is also affixed to the unit.

6.Ratings have been confirmed by the Hydronics Institute, Section of AHRI.

UNIT EQUIPPED FOR

HIGH ALTITUDE

3,000 FT. TO 12,000 FT.

7

Page 7
Image 7
Lochinvar 399 Ratings, Knight XL Boiler I=B=R Rating, Other Specifications, Installation & Operation Manual, Notes