Installation & Operation Manual
13 Diagrams (continued)
Figure 13-2 Ladder Diagram
|
|
| BOX DEPICTS |
|
|
| OPTIONAL ITEMS |
120VAC | JUNCTION BOX | NEUTRAL | GROUND |
|
|
| LOW VOLTAGE |
TERMINAL STRIP |
| TERMINAL STRIP | 120 VAC |
120V SUPPLY "L" |
| 120V SUPPLY "N" |
HIGH VOLTAGE
ON / OFF
SWITCH
JUNCTION
BOX
MANUAL RESET
HIGH LIMIT
| PC | |
BELLALARM | INTERFACE | |
| ||
SWITCH | ||
| ||
SILENCING | ||
|
INTEGRATED CONTROL |
|
|
| L |
| L | ||
|
|
|
| SYSTEM PUMP |
|
| ||
F5 |
|
| RELAY |
| IN | SYSTEM | OUT | |
|
|
|
|
|
|
| ||
|
|
|
|
|
|
|
| |
5A |
| SYSTEM PUMP |
|
|
|
| PUMP |
|
|
|
|
|
| CONTACTS |
| ||
|
| RELAY |
|
|
|
|
| |
|
|
|
|
|
|
|
| |
|
|
|
| BOILER PUMP |
|
|
|
|
|
|
| RELAY |
|
|
| SYSTEM | |
|
|
|
|
|
|
| BOILER | PUMP |
|
| BOILER PUMP |
|
|
|
| PUMP |
|
|
| RELAY |
|
|
|
| CONTACTS |
|
|
|
|
| DHW PUMP |
|
|
|
|
|
|
| RELAY |
|
|
|
| |
|
|
|
|
|
|
| BOILER | |
|
|
|
|
|
|
|
| |
|
| DHW PUMP |
|
|
|
| DHW | PUMP |
|
|
|
|
|
|
| ||
|
| RELAY |
|
|
|
| PUMP |
|
|
|
|
|
|
|
| CONTACTS |
|
|
|
|
| BLOWER |
|
|
|
|
| F4 |
| 1 | 2 |
|
|
| |
|
|
|
|
|
|
|
| DHW |
| 3.5A | BLOWER |
|
|
|
| RELAY BOARD | PUMP |
F3 |
| RELAY |
| 3 |
|
|
|
|
|
|
|
|
|
|
| ||
1.25A |
|
|
|
|
|
|
|
|
| 120 VAC | JUNCTION BOX |
|
|
|
| ||
|
|
|
|
|
| |||
F2 |
|
|
|
|
|
|
| |
3.5A | 24 VAC | RESISTOR | CONNECTION BOARD |
| ||||
|
|
|
|
| ||||
|
|
|
|
|
|
| ||
CONNECTION |
|
|
|
|
|
|
| |
BOARD |
|
|
|
| INTEGRATED | |||
|
|
|
|
| LWCO |
|
| |
|
|
| CONNECTION |
|
| CONTROL | ||
|
| FLOW |
|
|
| |||
|
|
| BOARD |
|
|
|
| |
|
| SWITCH |
|
| ||||
|
|
|
|
|
|
| ||
|
| ROOM THERMOSTAT |
|
|
|
|
| |
|
| ZONE CONTROL |
|
|
| |||
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
|
| DHW |
|
|
|
|
|
|
|
| THERMOSTAT |
|
|
| |||
|
|
|
|
|
|
| ||
|
| CONNECTION | LOW GAS | HIGH GAS |
| |||
|
|
|
|
| ||||
|
|
|
| BOARD | PRESSURE | PRESSURE |
|
|
|
|
| SWITCH | SWITCH | ||||
INTEGRATED |
|
|
|
|
| |||
|
|
|
|
|
|
| ||
CONTROL |
|
| INTEGRATED |
|
|
| ||
|
|
|
| CONTROL | AUX. DEVICE |
| ||
|
|
|
|
|
| PILOT SUPPLY |
|
|
DISPLAY |
|
|
|
| 24VAC |
| ||
|
|
|
|
|
|
| ||
|
|
|
|
|
| AUX. DEVICE |
| |
|
|
|
|
|
| PROVING |
| |
|
|
|
|
|
| |||
|
|
|
|
|
|
|
X3 |
| AIR PRESSURE | |
| |||
|
| SWITCH | |
| RIBBON CABLE |
| |
|
| X8 | |
|
|
| |
|
| BLOCKED | |
| DRAIN SWITCH | ||
|
|
|
INLET | S2 |
|
| |
SENSOR |
|
|
| |
|
|
|
| |
| S1 |
|
| |
OUTLET | GAS VALVE |
| ||
SENSOR |
|
|
|
|
| S3 |
| GAS VALVE | |
FLUE | RELAY | |||
|
|
| ||
SENSOR |
|
|
| |
|
|
|
| |
|
| BLOWER | 1 | |
CONNECTION BOARD |
|
|
|
|
|
| ||||
| ||||||
| CONTACTS |
|
|
| ||
|
|
|
|
| ||
|
|
|
| |||
|
| ALARM | ||||
| CONTACTS |
|
|
| ||
|
|
|
|
| ||
|
| S6 |
| |||
SYSTEM | ||||||
| ||||||
SENSOR |
|
|
| |||
(AUX) DHW |
| S4 | ||||
|
|
| ||||
TANK |
|
| ||||
SENSOR | S5 |
|
| |||
|
|
|
| |||
OUTDOOR | ||||||
| ||||||
SENSOR |
|
|
| |||
SHIELD |
|
|
| |||
| ||||||
| A |
| ||||
RS485 |
| |||||
B |
| |||||
|
| |||||
SHIELD |
| |||||
| ||||||
EXTERNAL + |
| |||||
CONTROL | - | |||||
|
|
| ||||
|
|
|
|
|
2
4
5
TR1
FLAME ROD
SPARK
ROD
CAUTION HIGH VOLTAGE SPARK LEAD
NOTES:
1.Where possible, switches are shown without utilities (gas, water or electricity) connected to the unit. As such, actual switch states may vary from those shown on diagrams depending upon whether utilities are connected or a fault condition is present.
2.See wiring diagram for additional notes.
LADDER DIAGRAM
LBL2356 REV C
73