Lopi Yankee Bay Pellet Insert 4Maintenance, Check Firepot for Clinkers, Cleaning the Firepot

Models: Yankee Bay Pellet Insert

1 40
Download 40 pages 38.74 Kb
Page 24
Image 24

2 4Maintenance

Daily Maintenance (whenever using the heater) - Continued

Check Firepot for Clinkers

If the flames seem to be coming only from the sides, or are orange/black, turn the heater off and check for clinkers.

The most likely causes are:

• Restrictor needs adjustment (see “Restrictor Adjustment” in the installation section of this manual)

• Poor pellet quality

• The door or glass has an air leak

• The exhaust system requires cleaning

Cleaning the Firepot

WARNING:

Make sure the heater has fully cooled (approximately 25 minutes) before opening the door and conducting service.

To clean the firepot, open the door (see page 26) and knock away any debris on the firepot with a screwdriver. If severely clogged, remove the firepot to gain better access.