3 0Maintenance

Yearly Maintenance (or every two tons) - Continued

Clean the Exhaust Blower (make sure the heater is cool and unplugged)

a

Remove the surround panels and access

 

 

the left side of the heater. Remove the

 

shroud covering the blower motor.

b

Remove the six screws holding the

exhaust blower motor in place.

11/32" Socket

c

Pull the motor out (be careful not

to damage the wiring or blades).

 

Exhaust Box

 

Blower

 

Blades

Cover

Plate

e

Remove the cover

plate over the

 

exhaust duct.

Exhaust

Blower

Motor

Housing

Clean the blower blades, blower housing, d and exhaust box. You may wish to use a vacuum to pull ash out of the vent system.

When replacing the motor, take care to align the gasket (if it is damaged, replace).

7/16" Nutdriver

 

 

g Clean the 1/2” air space

 

 

beneath the unit (use a

f

Use a vacuum or bottle brush to remove all

vacuum cleaner or brush).

 

flyash from the exhaust duct (if the gasket on

 

 

the cover plate is damaged, replace).

 

Clean the Vent (make sure the heater and vent is cool)

Make sure the cap is free of debris (especially if it has a screen that could become blocked).

Check the vent sections for creosote accumulation (indicating a poorly burning stove). Accumulation over 1/4” must be removed.