Message

Problem

Suggested Solution

 

 

The following SCSI IDs

The physical drives with

Make sure the physical

 

 

are not responding:

SCSI IDs a, b, and c are

drives are properly

 

 

Channel x:a.b.c

not responding on SCSI

connected and are

 

 

 

channel x.

powered on.

 

 

 

 

 

 

Other BIOS Error Messages

 

Message

Problem

Suggested Solution

 

 

Following SCSI

The physical disk roaming

Reconfigure the array.

 

 

disk not found

feature did not find the physical

 

 

 

and no empty

disk with the displayed SCSI

 

 

 

slot available for

ID. No slot is available to map

 

 

 

mapping it

the physical drive. MegaRAID

 

 

 

 

cannot resolve the physical

 

 

 

 

drives into the current

 

 

 

 

configuration.

 

 

 

Following SCSI

The physical drive roaming

Remove the drive or drives

 

 

IDs have the

feature found the same data on

that should not be used.

 

 

same data y, z

two or more physical drive on

 

 

 

Channel x: a, b,

channel x with SCSI IDs a, b,

 

 

 

c

and c. MegaRAID cannot

 

 

 

 

determine the drive that has the

 

 

 

 

duplicate information.

 

 

 

Unresolved

The configuration stored in the

Press a key to run MegaRAID

 

 

configuration

MegaRAID NVRAM does not

Manager.

 

 

mismatch

match the configuration stored

 

 

 

between disks

on the drives.

Choose View/Add

 

 

and VRAM on

 

Configuration from the

 

 

the adapter

 

Configure menu.

 

 

 

 

Use View/Add Configuration

 

 

 

 

to examine both the

 

 

 

 

configuration in NVRAM and

 

 

 

 

the configuration stored on

 

 

 

 

the disk drives. Resolve the

 

 

 

 

problem by selecting one of

 

 

 

 

the configurations.

 

 

 

 

 

 

Chapter 8 Troubleshooting