| Message | Problem | Suggested Solution |
|
| The following SCSI IDs | The physical drives with | Make sure the physical |
|
| are not responding: | SCSI IDs a, b, and c are | drives are properly |
|
| Channel x:a.b.c | not responding on SCSI | connected and are |
|
|
| channel x. | powered on. |
|
|
|
|
|
|
Other BIOS Error Messages
| Message | Problem | Suggested Solution |
|
| Following SCSI | The physical disk roaming | Reconfigure the array. |
|
| disk not found | feature did not find the physical |
|
|
| and no empty | disk with the displayed SCSI |
|
|
| slot available for | ID. No slot is available to map |
|
|
| mapping it | the physical drive. MegaRAID |
|
|
|
| cannot resolve the physical |
|
|
|
| drives into the current |
|
|
|
| configuration. |
|
|
| Following SCSI | The physical drive roaming | Remove the drive or drives |
|
| IDs have the | feature found the same data on | that should not be used. |
|
| same data y, z | two or more physical drive on |
|
|
| Channel x: a, b, | channel x with SCSI IDs a, b, |
|
|
| c | and c. MegaRAID cannot |
|
|
|
| determine the drive that has the |
|
|
|
| duplicate information. |
|
|
| Unresolved | The configuration stored in the | Press a key to run MegaRAID |
|
| configuration | MegaRAID NVRAM does not | Manager. |
|
| mismatch | match the configuration stored |
|
|
| between disks | on the drives. | Choose View/Add |
|
| and VRAM on |
| Configuration from the |
|
| the adapter |
| Configure menu. |
|
|
|
| Use View/Add Configuration |
|
|
|
| to examine both the |
|
|
|
| configuration in NVRAM and |
|
|
|
| the configuration stored on |
|
|
|
| the disk drives. Resolve the |
|
|
|
| problem by selecting one of |
|
|
|
| the configurations. |
|
|
|
|
|
|
Chapter 8 Troubleshooting | 111 |