4 Features

 

MegaRAID Enterprise 1600 64-Bit LVD has four SCSI channels that support 160M and Wide

 

SCSI, with data transfer rates of up to 160 MB/s per SCSI channel. Each SCSI channel supports up

 

to 15 Wide devices and up to seven non-Wide devices.

Features

MegaRAID features include:

 

• remote configuration and array management through MegaRAID WebBIOS

 

• high performance I/O migration path while preserving existing PCI-SCSI software

 

• SCSI data transfers up to 160 MB/s

 

• synchronous operation on a wide LVD SCSI bus

 

• up to 15 LVD SCSI devices on the wide bus

 

• up to 128 MB of 3.3V SDRAM cache memory in one single-sided or double-sided DIMM socket

 

 

(Cache memory is used for read and write-back caching and for RAID 3 and RAID 5 parity generation.)

 

• NVRAM storage for RAID configuration data

 

audible alarm

 

DMA chaining support

 

separate DRAM bus

 

• support for differential or single-ended SCSI with active termination

 

• up to 12 MegaRAID Enterprise 1600 adapter cards per system

 

• support for up to 15 SCSI devices per channel

 

• support for RAID levels 0, 1, 3, 5, 10, 30, and 50

 

• span depth of eight for RAID 1, 3 or 5 arrays

 

• support for scatter/gather and tagged command queuing

 

• ability to multithread up to 256 commands simultaneously

 

• support for multiple rebuilds and consistency checks with transparent user-definable priority setting

 

• support for variable stripe sizes for all logical drives

 

• automatically detection of failed drives

 

• automatic and transparent rebuild of hot spare drives

 

• hot swap of new drives without taking the system down

 

• optional battery backup for up to 72 hours of data retention

 

server clustering support

 

• optional firmware provides multi-initiator support

 

server failover

 

• software drivers for major operating systems

SMART Technology

The MegaRAID Self-Monitoring Analysis and Reporting Technology (SMART) detects up to 70% of all predictable drive failures. SMART monitors the internal performance of all motors, heads, and drive electronics. You can recover from drive failures through RAID remapping and online physical drive migration.

Chapter 4 Features

25